TT-PADM: A Time-Driven Transformer Diffusion Model for Robust Sparse-View and Limited-View Photoacoustic Tomography
Jiawei Zheng1,2,3, Wende Dong4, Junjun Sun3,5
1Department of Anesthesiology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui 230001, China.
Abstract:
Objective: To develop a high-performance reconstruction framework that enables high-quality photoacoustic tomography (PAT) imaging under limited-view and sparse-view acquisition constraints. Impact Statement: The proposed method reduces the number of required acoustic transducers while maintaining image quality comparable to full-view systems, providing a practical and cost-efficient solution for biomedical PAT imaging. Introduction: PAT offers high-resolution visualization of biological tissues. However, restrictions such as reduced transducer counts or incomplete detection geometries render the inverse problem severely ill-posed, leading to marked degradation in reconstructed images. Although diffusion models have recently shown strong promise for image restoration, existing architectures can be computationally intensive or insufficiently expressive for the complexities of PAT.Methods: We introduce a time-driven transformer-based photoacoustic diffusion model (TT-PADM) that directly restores high-quality images from limited-view and sparse-view PAT reconstructions. TT-PADM uses a time-driven transformer within a time-dependent noise-estimation network, reducing model parameters by over 80% relative to conventional transformer designs while enhancing the generative capacity of the diffusion process. Results: Simulations and experimental results show that TT-PADM delivers high-fidelity reconstructions even under severely limited acquisition conditions, producing image quality comparable to full-view PAT systems. Quantitative and qualitative analyses show that TT-PADM consistently surpasses state-of-the-art reconstruction approaches, providing notable improvements in structural accuracy and noise suppression. Conclusion: TT-PADM offers a robust, parameter-efficient, and highly effective solution for PAT image restoration under practical hardware constraints, with strong potential for deployment in resource-limited biomedical imaging scenarios.
More Related Videos
05:32A High-performance Compact Photoacoustic Tomography System for In Vivo Small-animal Brain Imaging
Published on: June 21, 2017
06:45Author Spotlight: Integrated Photoacoustic, Ultrasound, and Angiographic Tomography (PAUSAT) for NonInvasive Whole-Brain Imaging of Ischemic Stroke
Published on: June 2, 2023
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography