Related Experiment Video
Updated: Mar 6, 2026

Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
Published on: January 18, 2021
Comparative analysis of artificial intelligence-based contouring of cardiac substructures on computed tomography
Alexandra Moignier1, Tanguy Perennec2, Elise Prangères1
1Medical Physics Department, Institut de Cancérologie de l'Ouest, Saint Herblain, France.
Background And Purpose:
Artificial intelligence-based contouring tools enable assessment of radiation doses to cardiac substructures beyond mean heart dose. This study examined inter-solution variations in raw contours and the impact of non-contrast enhancement on contours for each solution.
Materials And Methods:
Contrast-enhanced (CE) and non-contrast-enhanced (NCE) breath-hold thoracic computed tomography (CT) scans, sequentially acquired during the same imaging session for twenty lung cancer patients, were used. Seven commercial, three open-source, and one in-house AI solutions were evaluated. On CE-CTs, solutions were compared using Dice Similarity Coefficient (DSC) and 95th percentile of Hausdorff distance (HD95) across each pair of solutions. Then, the effect of non-contrast enhancement on contours was assessed using volume ratios between NCE-CT and CE-CT for each solution.
Results:
Typically, ten cardiac substructures were contoured by most of the solutions. For the whole heart, cardiac chambers and great vessels, the average median DSC was above 0.8 for 55 of the 123 structure-solution pairs (45%), and the average median HD95 was below 10 mm for 47 of the 123 structure-solution pairs (38%). For the coronary arteries, the average median DSC ranged between 0.03 and 0.50 and the average median HD95 ranged between 19 mm and 70 mm. Non-contrast enhancement influenced results variably; volume differences were below 10% for 84 of the 123 structure-solution pairs (68%).
Conclusions:
Automatic contouring solutions exhibited inter-solution variability for cardiac substructures that may have clinical impact. Greater transparency and standardisation of models, ideally through international consensus and shared datasets, are essential.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography