Related Experiment Video
Updated: Mar 6, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Computer-Aided Analysis of Photographed Chest X-Ray Films Performs Well Compared With Trained Radiologists
Zerubabel Desita1, Temesgen Tadesse1, Anders Solitander Bohlbro2,3
1Department of Radiology, College of Medicine and Health Science, University of Gondar, Ethiopia.
Objective:
To assess whether computer-aided detection (CAD) chest X-ray (CXR) software may aid physicians in low-resource, high tuberculosis (TB) endemic settings where radiologists are scarce.
Patients And Methods:
A retrospective pilot study was conducted on CXR films taken between January 1, 2017, and March 30, 2018, in Guinea-Bissau and Ethiopia to compare the interpretation of CXRs regarding pulmonary TB (PTB) by CAD (qXR; Qure.ai) with that of 2 experienced Ethiopian radiologists (A and B). To improve the applicability of this method in low-resource settings, an analysis was performed on images of CXRs taken by mobile phones. Two reference standards were applied: final PTB diagnosis by clinical or laboratory findings (ie, Xpert MTB/RIF [Xpert]-confirmed PTB).
Results:
We included 498 CXRs from patients seeking help for TB indicative symptoms. Radiologist A identified 50, radiologist B identified 99, and the software identified 81 as indicative of TB. The overall area under the curve for the receiver-operating characteristic curve of the software was 0.84 for Xpert-confirmed cases. At the prechosen cutoff value of 0.5, the sensitivity of CAD CXR was 76.5%, and the specificity was 85.9%. Radiologist A's assessments were 64.7% sensitive and 91.9% specific, whereas radiologist B's assessments were 76.5% sensitive and 82.3% specific for Xpert-confirmed cases. The agreement regarding TB-related findings between the radiologists combined (κ=0.45) and each radiologist and the software (κ=0.56) was moderate.
Conclusion:
Our study revealed that CAD CXR performs comparably with experienced radiologists when it is applied to CXR films, photographed by mobile phones and a digital camera with similar sensor resolutions.
Trial Registration:
PACTR201611001838365.
More Related Videos
08:05Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT