Abstract:
Background and objectives Bile leaks are serious complications that can occur after liver transplant, hepatobiliary surgery, and abdominal trauma and can be challenging to diagnose. Noninvasive diagnostic studies for bile leaks are limited. In this study, we aimed to evaluate the efficacy of MRI with a double-dose of Eovist (gadoxetate disodium) in comparison with other imaging modalities for detecting biliary leaks. Methods This study involved a retrospective review of patients who underwent MRI with double-dose Eovist (dEovist) to evaluate suspected bile leakage from 2016 to 2022. Indications for evaluation included suspected bile leak after recent hepatobiliary surgery or penetrating right upper quadrant trauma. Once the dEovist study was performed and a bile leak was suspected, confirmation with endoscopic retrograde cholangiopancreatography (ERCP) was obtained. These results were statistically analyzed to determine the sensitivity and specificity of MRI with dEovist in detecting biliary leakage, and ERCP was used as the confirmatory test. Results A total of 19 patients were included. dEovist detected biliary leakage in five of 19 patients. All patients with concern for bile leak after MRI underwent ERCP for confirmation of the findings; four of these patients were confirmed as true positives, and one was determined to be a false positive. The remaining 14 patients with negative MRI findings with dEovist were followed clinically, and all had clinical courses that were not suggestive of bile leak. Six of these patients underwent ERCP, which also confirmed the absence of biliary leakage. The sensitivity of MRI with dEovist for detecting bile leaks in this study was 100% (95% confidence interval (CI): 39%, 100%), and the specificity was 93% (95% CI: 66%, 100%). Conclusions Prompt identification and early intervention are crucial for preventing the complications associated with bile leaks. The use of MRI with dEovist has shown promising results as a noninvasive imaging modality with high sensitivity and specificity in the detection of bile leaks.
Insights
Magnetic Resonance Imaging (MRI) with double-dose Eovist effectively detects bile leaks after surgery or trauma. This noninvasive method shows high accuracy, aiding prompt diagnosis and treatment of biliary complications.
Area of Science:
- Hepatobiliary Imaging
- Diagnostic Radiology
- Medical Imaging Techniques
Background:
- Bile leaks are significant complications following liver transplant, hepatobiliary surgery, and trauma.
- Accurate and timely diagnosis of bile leaks is often challenging due to limited noninvasive methods.
Purpose of the Study:
- To evaluate the efficacy of MRI with a double dose of Eovist (gadoxetate disodium) for detecting biliary leaks.
- To compare the diagnostic performance of MRI with double-dose Eovist against other imaging modalities.
Main Methods:
- Retrospective review of 19 patients evaluated with MRI using double-dose Eovist (dEovist) from 2016-2022.
- Indications included suspected bile leak post-hepatobiliary surgery or trauma.
- Endoscopic retrograde cholangiopancreatography (ERCP) was used as the confirmatory test.
Main Results:
- MRI with dEovist detected biliary leakage in 5 of 19 patients.
- Sensitivity was 100% and specificity was 93% for MRI with dEovist in detecting bile leaks.
- ERCP confirmed 4 true positives and 1 false positive; negative MRI findings were clinically validated.
Conclusions:
- MRI with double-dose Eovist demonstrates high sensitivity and specificity for detecting bile leaks.
- This noninvasive imaging modality shows promise for prompt identification and management of biliary leakage.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...