Accuracy of Intraocular Lens Power Calculation Formulas in Cataract Eyes after Vitrectomy with Silicone Oil
Peng Zhao1,2, Meng Li2, Zhao-Xing Guo2
1School of Clinical Medicine, Shandong Second Medical University, Weifang, China.
Ophthalmic Research
|March 5, 2026
Summary
Newer artificial intelligence formulas, particularly Kane and EVO, offer superior accuracy for intraocular lens calculations in eyes with silicone oil after vitrectomy compared to traditional methods.
Area of Science:
- Ophthalmology
- Artificial Intelligence
- Biomedical Engineering
Background:
- Cataract surgery requires precise intraocular lens (IOL) power calculation.
- Vitrectomy with silicone oil tamponade presents unique challenges for IOL calculation accuracy.
- Traditional formulas may not perform optimally in these complex cases.
Purpose of the Study:
- To systematically compare the accuracy of artificial intelligence (AI) and traditional IOL calculation formulas.
- To evaluate formula performance in eyes that have undergone vitrectomy with silicone oil tamponade.
- To identify the most accurate formulas for this specific patient population.
Main Methods:
- A meta-analysis of studies published up to October 29, 2025, from major databases (PubMed, Cochrane, Embase, Web of Science).
- Inclusion of 12 IOL calculation formulas: SRK/T, Hoffer Q, Hoffer QST, Haigis, Barrett Universal II, Holladay I, Holladay II, RBF, LSF, EVO, Kane, and Pearl-DGS.
- Primary outcomes measured were the percentage of eyes with prediction errors (PE) within ±0.50D and ±1.00D.
Main Results:
- The meta-analysis included 7 studies with 1060 eyes.
- Newer AI-driven formulas demonstrated higher accuracy than traditional formulas.
- The Kane formula showed the highest precision for prediction errors within ±0.50D.
- The EVO formula performed best for prediction errors within ±1.00D, with Kane also ranking highly.
- The RBF formula also demonstrated strong performance.
Conclusions:
- The Kane and EVO formulas are recommended as superior choices for IOL power calculation in eyes filled with silicone oil after vitrectomy.
- These advanced formulas offer improved accuracy over traditional methods in complex post-vitrectomy eyes.
Related Concept Videos
Glaucoma: Overview
1.6K
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.6K
Focusing of Light in the Eye
6.8K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
6.8K
Angle Closure Glaucoma: Treatment
1.5K
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.5K