Low concentration isotonic iodixanol on hepatic and portal veins imaging quality and renal function: A 320-detector
Jingjing Wu1, Zhengyang Gao, Guihua Li
1Department of Radiology, Hospital of Honghe State affiliated to Kunming Medical University, First People's Hospital of Honghe Prefecture, Gejiu, Yunnan, China.
Background:
The effects of different concentrations of isotonic contrast agents on the quality of hepatic and portal vein imaging and their impact on patients' renal function remain unclear. This study aimed to assess whether lower concentrations of iodixanol yield high-quality imaging by comparing hepatic and portal vein imaging quality and evaluating renal function following dual-energy CT (DECT) scans.
Methods:
Patients were randomly assigned to receive either iodixanol at 270 mgI/mL (iodixanol 270 group, n = 50) or 320 mgI/mL (iodixanol 320 group, n = 50) and underwent DECT with energy-spectrum reconstruction. Quantitative and qualitative image quality parameters, as well as changes in renal function before and after scanning, were compared between the 2 groups.
Results:
Significant differences were observed in the contrast-to-noise ratio, signal-to-noise ratio of the main portal vein, and the computed tomography value of the hepatic vein between the 2 groups (P < .05). These parameters were superior in the iodixanol 320 group compared to the iodixanol 270 group. Qualitative evaluation scores for the portal and hepatic veins in the iodixanol 320 group were significantly higher than those in the iodixanol 270 group (P < .05). Postcontrast acute kidney injury incidence was higher in the iodixanol 320 group than in the iodixanol 270 group (20.5% vs 2.1%, P < .05), and this association remained significant after multivariable adjustment (adjusted odds ratio = 13.70, P = .002).
Conclusion:
With a fixed injection protocol, iodixanol 320 mgI/mL yielded higher venous enhancement, whereas iodixanol 270 mgI/mL provided diagnostically acceptable portal/hepatic venous image quality on DECT with a lower iodine load. After adjustment, 320 mgI/mL was associated with higher odds of postcontrast acute kidney injury; this safety signal requires confirmation in larger iodine-matched studies.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
11:10Visualization of Vascular and Parenchymal Regeneration after 70% Partial Hepatectomy in Normal Mice
Published on: September 13, 2016
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Hepatic Portal System
At its core, the hepatic portal vein is the result of a confluence of the superior and inferior mesenteric veins along with the splenic vein. Each of these veins has a unique role. The superior mesenteric vein is...