Sound levels in single vs. double bed ICU rooms: A high-resolution sound study
Mathias Bader1, Maximilian Niederer1, Sascha Hammer1
1Department of Anaesthesiology and Intensive Care, Medical University of Graz, Austria.
Objectives:
High sound levels in intensive care units lead to increased rate of delirium and sleep disturbances in patients but also decreased work performance of healthcare providers. It is unclear how much impact different architectural settings have. The study aimed to determine whether sound levels in ICUs differ between single- and double-bed rooms.
Methods:
This prospective observational study collected sound level data in three architecturally identical ICUs at the Medical University of Graz. Recordings were made every 5 s, then aggregated into 1-minute and subsequently hourly intervals. For each hour, mean (LAeq), minimum (LAmin), and maximum (LAmax) sound pressure levels and standard deviations were calculated. Hourly sound levels between single- and double-bed rooms were compared by independent-samples t-tests. Secondary analyses examined day-night differences. All values were compared against WHO guideline thresholds.
Results:
A total of 188 ICU patients were included, generating over 11 million sound data points. Contrary to expectations,single-bed rooms exhibited significantly higher LAeq(51.85 dBA vs. 50.29 dBA;p = 0.026),higher LAmin(41.22 dBA vs. 35.34 dBA;p < 0.001), andlower LAmaxcompared to double-bed rooms (67.80 dBA vs. 70.89 dBA;p = 0.023). Across all room types, sound levels were significantly higher during daytime for all parameters. None of the hourly values met WHO sound thresholds.
Conclusions:
Single-bed ICU rooms showed higher average and baseline sound exposure than double-bed rooms, challenging assumptions about acoustic advantages of single occupancy. Sound levels always remained above international recommendations.
Implications For Clinical Practice:
These findings highlight the need for multimodal strategies to reduce ICU sound, including staff awareness, alarm management, and architectural considerations. Structural design alone is insufficient; targeted behavioural and environmental interventions are essential to create quieter ICU environments.
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Hospitals-II
Nurses that work in...
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.