Effect of Region-of-Interest Prompting on Gemini 2.5 Pro in MRI Classification of Anterior Cruciate Ligament Injury
Nitin Chetla1, Shivam Patel2, Luis Rodriguez3
1Medicine, University of Virginia School of Medicine, Charlottesville, USA.
Background:
Artificial intelligence (AI) has shown promise in musculoskeletal imaging, yet the diagnostic contribution of large language models (LLMs) remains unclear. Prompt engineering may critically shape performance.
Objective:
To evaluate the diagnostic accuracy of Google Gemini 2.5 Pro in classifying anterior cruciate ligament (ACL) status on knee magnetic resonance imaging (MRI) and to compare three prompting strategies; the primary endpoint was weighted F1-score.
Methods:
A retrospective diagnostic study used 150 proton-density fat-suppressed (PD-FS) knee MRI volumes (50 each: healthy, partially injured, completely ruptured) drawn from a publicly available dataset (Clinical Hospital Centre Rijeka, Croatia; 2006-2014). Gemini 2.5 Pro received multimodal inputs via the official Python software development kit (SDK). Three prompts were tested: (P1) general series prompt, (P2) technical-description prompt, and (P3) region-of-interest (ROI)-focused prompt. Outputs (A = healthy, B = partial, C = ruptured) were compared with radiologist labels. Accuracy, precision, recall, specificity, F1 score, confusion matrices, and mean inference time were computed (scikit-learn v1.5.0). Ethical approval was waived because the data were de-identified and publicly available.
Results:
Mean inference time was 2.1 ± 0.3 seconds per volume. ROI prompting (P3) yielded the highest weighted F1-score (0.31), while macro recall (0.35) and macro specificity (0.67) were similar across prompts. Confusion matrices showed improved discrimination of completely ruptured ACLs with P3.
Conclusions:
Despite a minor improvement in the weighted F1-score with Prompt 3, all prompts demonstrate poor overall classification performance, with low sensitivity and accuracy. The consistently overlapping confidence intervals indicate that prompt variations alone are insufficient to meaningfully enhance model performance. These findings suggest fundamental limitations in the model's ability to handle this task rather than suboptimal prompting.
More Related Videos
06:27Author Spotlight: Investigating Early Events and Long-Term Effects of ACL Injuries for Osteoarthritis Progression
Published on: September 29, 2023
09:33Neuronavigated Focalized Transcranial Direct Current Stimulation Administered During Functional Magnetic Resonance Imaging
Published on: November 15, 2024
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
