Stability at a Cost: Evaluating Postoperative Complications in Bioabsorbable vs. Metallic Syndesmotic Fixation: A
Andy Suarez1, Leon Liu1, Taylor Checkley1
1Health Professions Division, Nova Southeastern University Dr. Kiran C. Patel College of Allopathic Medicine, Fort Lauderdale, USA.
None:
The use of bioabsorbable screws for syndesmotic fixation in complex ankle fractures has become increasingly popular, as they may eliminate the need for secondary surgeries for implant removal. However, their efficacy when compared against metallic screws is unclear, with some persisting concerns of higher complication rates compared to the traditional metallic option. A systematic search was conducted using PubMed and Google Scholar, yielding 332 studies. After title and abstract screening followed by full-text review, eligible randomized controlled trials comparing bioabsorbable versus metallic screw fixation in ankle syndesmotic injuries were included. The total rate of postoperative complications was primarily assessed. Risk ratios (RR) and 95% confidence intervals (CIs) were calculated. Four studies met the inclusion criteria for the meta-analysis, encompassing 257 patients. The pooled data demonstrated a significantly higher risk of complications with bioabsorbable screw fixation, including revision surgery, infection, and symptomatic hardware removal, compared to metallic screws (RR 3.35, 95% CI 1.75-6.42, p = 0.0003). Range-of-motion outcomes varied across studies but showed no clear superiority of either fixation method. The increased complication rate with bioabsorbable screws raises concerns about routine use in syndesmotic fixation. Although previous studies have suggested comparable functional outcomes and fewer reoperations due to implant removal, the current data underscore the importance of prioritizing safety and reliability. Given the risk of inflammatory reactions and hardware failure seen in bioabsorbable groups, metallic screws remain the more dependable option. Future research should focus on improving the biomechanical and biocompatibility profiles of absorbable materials before they are widely adopted in clinical use.
More Related Videos
Related Concept Videos
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Bioavailability Study Design: Healthy Subjects Versus Patients
Bioavailability Enhancement: Drug Stability Enhancement and GI Retention
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Toxicity Testing in Animals