Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
A Pilot Study Examining the Convergent Validity of Two Commercially Available Heart Rate Monitoring Devices During
Hope Reynolds1, Scott A Conger2, Brian C Rider1
1Department of Kinesiology, Hope College, Holland, MI, USA.
Abstract:
The purpose of this study was to determine the feasibility of heart rate (HR) monitoring using an optical monitor (OHR) across different swimming strokes and intensities. Nineteen collegiate swimmers (7M, 12F) completed two swimming protocols (P1: nine 75m freestyle swims at three intensities, P2: two 100m swims using their preferred stroke). During P1, four swimming bouts were completed at light intensity (HR 145-155 beats per minute [bpm]), three at moderate intensity (HR 155-170bpm) and two at vigorous intensity (HR > 170bpm). During P2, participants completing one swimming bout using their preferred stroke (freestyle [n=7], backstroke [n=5], breast stroke [n=4], and butterfly [n=3]) at moderate intensity and one vigorous intensity with one-minute rest between each swim. A repeated measures ANOVA (RM ANOVA) with post hoc analysis was completed between the OHR and a traditional chest monitor (THR) with significance set at p<0.05. There was an overall significant difference between mean OHR and THR (OHR: 150.7 ± 17.0 vs. THR: 155.9 ± 19.0 bpm, p=0.02) and significant differences during the recovery stage between P1 and P2 (OHR: 126.1 ± 17.8 vs. THR: 122.3 ± 18.0 bpm, p=0.007) and the first 100m swim of P2 (OHR: 148.3 ± 21.3 vs. THR: 159.1 ± 20.1 bpm, p=0.002). The OHR monitor captured 99.9 ± 0.1% of the HR data whereas the THR captured only 58.98 ± 31.3% of the participants' HR data. The OHR significantly underestimated HR compared to the THR but more consistently captured HR than the THR throughout the duration of the swim test.
More Related Videos
09:24A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
05:48Autonomic Function Following Concussion in Youth Athletes: An Exploration of Heart Rate Variability Using 24-hour Recording Methodology
Published on: September 21, 2018
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Special considerations while measuring pulse