Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
Low-mechanical-index B-mode phase-inversion harmonic imaging significantly improves hepatic lesion conspicuity during
Jeongin Yoo1, Jeong Min Lee1,2, Hyo-Jin Kang1
1Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Purpose:
This study compared the imaging performance of low-mechanical-index phase-inversion harmonic imaging (low-MI PIHI) with conventional contrast-enhanced ultrasonography (CEUS) during the Kupffer phase (KP) of Sonazoid-enhanced imaging for visualizing hepatic lesions, focusing on lesion conspicuity and overall image quality.
Methods:
This prospective study was approved by the Institutional Review Board and included 71 patients with 72 focal liver lesions examined between February 2023 and January 2024. All patients underwent Sonazoid-enhanced CEUS. Three image sets were acquired for each lesion: baseline B-mode imaging, conventional KP imaging, and low-MI PIHI KP imaging. Two independent radiologists, blinded to clinical information, independently evaluated lesion conspicuity, border delineation, and overall image quality using a 5-point Likert scale.
Results:
Baseline B-mode imaging demonstrated the lowest lesion conspicuity scores, which improved with conventional KP imaging and were highest with low-MI PIHI KP imaging (all P<0.001). Compared with conventional KP imaging, low-MI PIHI KP imaging provided significantly higher lesion conspicuity for both reviewers (P<0.001), with the most pronounced improvement observed in hepatocellular carcinomas within cirrhotic livers, where conspicuity scores nearly doubled (P<0.001). Lesion border delineation also improved significantly for both reviewers (P<0.001). Overall image quality was consistently superior with low-MI PIHI KP imaging (P≤0.003). These advantages were particularly evident for small lesions (≤2 cm) and in cirrhotic liver backgrounds.
Conclusion:
Low-MI PIHI KP imaging significantly enhances hepatic lesion conspicuity and margin delineation compared with conventional CEUS harmonic imaging, while also improving overall image quality. These improvements may support more confident lesion detection and facilitate image-guided procedures.
More Related Videos
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...