Related Experiment Video
Updated: Mar 12, 2026

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Rapid and Efficient Aerosol Delivery During 60 L/min High Flow Nasal Cannula Therapy-In Vitro Development of a Novel
Casey Grey1, Ghali Aladwani1, Anya Maradiaga1
1Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, Virginia, 23284-3015, USA.
Abstract:
High flow therapy (HFT) delivers heated and humidified gas at flow rates up to 60 L/min to hypoxemic subjects, but is not conducive to simultaneous administration of pharmaceutical aerosols. Aerosol losses occur due to circuit wall impaction, environmental loss and particle growth from high humidity; resulting in poor lung delivery efficiency. This study compares two strategies for delivering dry powder aerosols during 60 L/min humidified HFT: a circuit connector (HFT-CC) which integrates directly into the standard HFT flow pathway, and an interface connector (HFT-IC) designed to bypass delivery line losses by directly injecting aerosol into the nasal prongs. Experiments were conducted using an anatomically-realistic in vitro adult nasal airway model with physiological breathing patterns, albuterol sulfate excipient enhanced growth (AS-EEG) dry powder formulation, air-jet aerosolization engine, and custom air actuation system. The HFT-CC approach improved lung delivery to 25.6% compared to existing published data (12.8%) but was limited by losses in the circuit tubing and nasal interface. The HFT-IC approach with a split nasal interface achieved 45.1% lung delivery (HFT-IC3), nearly a fourfold improvement from previously published results, by isolating aerosol flow from HFT flow and eliminating upstream losses. While nose-throat (NT) deposition in HFT-IC3 remained high (39.6%), this approach presents an attractive target for future computational and experimental optimization. These findings prove that efficient dry powder aerosol lung delivery during 60 L/min humidified HFT is achievable, laying the groundwork for translational advances in the efficient delivery of pulmonary therapies such as surfactants, antibiotics, anti-inflammatories, and antivirals during ventilatory support.
More Related Videos
07:28Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
05:43Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Suctioning the Nasopharyngeal Airway
Equipment Required
Inhaled Medications
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: