Related Experiment Video
Updated: Jun 11, 2026

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
Published on: July 15, 2009
How to optimise the use of innovative invasive devices: considerations for feasibility studies
Emily Hotton1,2, Julia Wade3,4, Daisy Elliott3,4
1Women and Children's Research Centre, Southmead Hospital, North Bristol NHS Trust, Bristol, UK. Emily.hotton@nhs.net.
Abstract:
Innovation in medical devices is essential for advancing patient care but has been undermined by inadequate evaluation and regulation. The UK vaginal mesh scandal exposed systemic flaws in medical device evaluation, where insufficient pre-market testing and ineffective post-market surveillance caused harm to countless women. Unlike pharmaceutical products, medical devices often enter clinical practice without robust evidence or long-term safety data. However, evaluation of devices can present methodological challenges, particularly when they are used during invasive procedures, given their multifaceted nature and contextual variables. Using the ASSIST study and the OdonAssist™ inflatable device for assisted vaginal birth as a case study, we wish to highlight these challenges and present a model for conducting feasibility studies of complex interventions. Early feasibility studies of the OdonAssist device demonstrated that although women accepted the innovation, the success rate of assisted vaginal birth was lower than anticipated. An embedded qualitative evaluation provided critical insights, revealing key factors influencing device use, design, and operator technique. The use of qualitative case study methodology allowed for systematic observation, stakeholder feedback, and iterative device refinement. For example, issues such as accidental activation of the deflation button were identified, leading to real-time design modifications in conjunction with industry partners. Stakeholder engagement-including patients, clinicians (doctors and midwives), ethics committees, and industry partners-was integral to optimising study design, device functionality, and training programmes. This collaborative, data-driven approach expedited the identification of modifications to device use, necessitating design changes and thereby ensuring device safety and usability. The evaluation of innovative devices like the OdonAssist requires a holistic approach that incorporates qualitative methodologies, stakeholder collaboration, and iterative feedback. Embedding case study research within feasibility trials ensures rapid identification of challenges, supports timely modifications, and fosters safer device implementation. Future research should explore video-recorded observations and enhanced patient feedback to refine device technique and training further.
More Related Videos
11:49Autologous Endothelial Progenitor Cell-Seeding Technology and Biocompatibility Testing For Cardiovascular Devices in Large Animal Model
Published on: September 9, 2011
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Related Concept Videos
Mechanical Efficiency of Real Machines
However, in reality, no machine can be truly ideal, and all of them experience some...
Factors Affecting Workability
Methods of Medium Optimization