Feed injection-enabled reversed phase liquid chromatography for simplified analysis of lipophilic drugs and
Daniel Foshag1, Stephan Buckenmaier1, Patrik Petersson2
1Liquid Phase Division, Agilent Technologies Deutschland GmbH, 76337 Waldbronn, Germany.
Abstract:
Strong sample solvents and lipidic excipients hamper reversed‑phase (RP) liquid chromatography (LC) analysis of lipid‑based pharmaceutical formulations by causing solvent mismatch, resulting in peak distortion and restricting the applicable injection volume, which ultimately reduces the sensitivity to detect impurities. In this work, we evaluated feed injection (FI) under gradient conditions for the analysis of sesame oil-based formulations dissolved in ethyl acetate (EtOAc) and integrated FI with two‑dimensional LC coupled to mass spectrometry (2D‑LC/MS) for impurity profiling. Findings were compared to conventional flow‑through injection (FTI) and sandwich injection, across injection volumes of 1-40 µL. FI at low feed flow fractions (≤ 5 % of mobile phase flow rate) provided ≥ 1:20 online dilution, sustaining column head focusing, and preserving peak shape and linearity across the full injection range. In contrast, higher feed flow fractions (≥ 20 % of the mobile phase flow rate, ≤ 1:5 dilution) resulted in severe fronting peaks and non-linear ultraviolet (UV) detector response. Finally, the 2D transfers resolved matrix‑ and Active Pharmaceutical Ingredient (API)‑related impurities without laborious offline reconstitution or dilution. This work extends the application field of FI from analyte diluents to complex lipid matrices, offering a robust, scalable workflow for pharmaceutical formulation analysis.
More Related Videos
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...