Challenges and unmet needs of [18F]fluorocholine PET in hyperparathyroidism: A framework for refining current
Martin W Huellner1,2, Shaza K Isenschmid3,4, Petra Petranović Ovčariček3,5,6
1Department of Nuclear Medicine, University Hospital of Zurich, Rämistrasse 100, Zurich, 8091, Switzerland. Martin.Huellner@usz.ch.
Abstract:
The advent of [18F]fluorocholine (FCH) positron emission tomography (PET)/computed tomography (CT) or magnetic resonance (MR) imaging has enhanced the diagnostic performance of preoperative imaging in patients with primary and renal hyperparathyroidism (HPT) during the past decade [1, 2]. Numerous studies and meta-analyses have confirmed the excellent performance of FCH PET, including in complex cases (i.e., inconclusive or negative results on parathyroid scintigraphy, recurrence, renal hyperparathyroidism (HPT), multiple endocrine neoplasia type 1 (MEN1)-related pHPT), with diagnostic accuracy consistently exceeding 95% in larger studies [3-11]. As a result, when available, FCH PET is a widely accepted first-line modality for primary and renal HPT [10]. Moreover, FCH PET offers several advantages over parathyroid scintigraphy, such as a lower radiation dose burden (especially if PET/MR is used) [12, 13], shorter acquisition times, and sustained cost-effectiveness [14-17]. Despite these advantages, there are several unmet needs that remain to be addressed. This editorial explores the remaining challenges associated with the use of FCH PET and underscores the need for close interdisciplinary collaboration among nuclear medicine physicians, endocrinologists, and surgeons to further optimize diagnostic and therapeutic strategies and address existing clinical gaps.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET