Quantitative flow ratio for assessment of donor vessel in patients with chronic total occlusions

Xinjian Li1,2,3,4, Juntao Duan1,2,3,4, Lin Mi1,2,3,4

  • 1Department of Cardiology and Institute of Vascular Medicine, Peking University Third Hospital, Beijing, China.

PubMed

Insights

Murray-law based quantitative flow ratio (µQFR) shows good agreement with 3D-QFR for assessing donor vessels in chronic total occlusion (CTO) patients. This simplifies functional assessment in complex coronary artery disease.

Area of Science:

  • Cardiology
  • Interventional Cardiology
  • Medical Imaging

Background:

  • Chronic total occlusion (CTO) presents a complex challenge in coronary artery disease, characterized by complete blockages and collateral circulation.
  • Donor vessels supplying collateral flow in CTO patients are susceptible to functional ischemia, necessitating accurate assessment.
  • Quantitative flow ratio (QFR) offers angiography-based functional assessment, with single-projection µQFR improving applicability.

Purpose of the Study:

  • To evaluate the agreement between single-projection Murray-law based quantitative flow ratio (µQFR) and three-dimensional quantitative flow ratio (3D-QFR).
  • To assess the functional status of donor vessels in patients with chronic total occlusion (CTO).

Main Methods:

  • A retrospective, single-center study included 336 patients with single-vessel CTO lesions.
  • Both µQFR and 3D-QFR were employed to functionally assess the predominant collateral donor artery.
  • Data were collected between January 2015 and June 2023.

Main Results:

  • A strong correlation was observed between µQFR and 3D-QFR (r=0.947, p<0.001).
  • The diagnostic accuracy of µQFR in estimating 3D-QFR was high at 96.1%.
  • Receiver operating characteristic (ROC) curve analysis yielded an area under the curve (AUC) of 0.984 for µQFR.

Conclusions:

  • µQFR demonstrates good correlation and agreement with 3D-QFR for functional assessment of donor vessels in CTO patients.
  • This suggests µQFR is a reliable method for evaluating donor vessel function in this patient group.