Related Experiment Video
Updated: Mar 14, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Sildenafil and N-desmethyl sildenafil quantification in human plasma by HPLC coupled with ESI-MS/MS detection:
Balasekhara Reddy Challa1,2, Bahlul Z Awen3, Babu Rao Chandu3
1Siddharth Institute of Pharmacy, Nalanda Educational Society, Kantepudi, Sattenapalli, Guntur, India, 522438. baluchalla_99@yahoo.com.
Abstract:
The present study aims at developing a simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of sildenafil and its metaboliteN-desmethyl sildenafil in human plasma using sildenafil-d8, N-desmethyl sildenafil-d8 as internal standards (IS). Chromatographic separation was performed on Zorbax SB C18, 4.6 × 75 mm, 3.5 μm column with an isocratic mobile phase composed of 10 mM ammonium acetate and acetonitrile (5/95 v/v), at a flow-rate of 0.6 ml min-1. Sildenafil, sildenafil-d8, N-desmethyl sildenafil and N-desmethyl sildenafil-d8 were detected with proton adducts at m/z 475.2 → 283.4, 483.4 → 283.4, 461.3 → 283.4 and 469.4 → 283.4 in multiple reaction monitoring (MRM) positive mode respectively. Both drug, metabolite and internal standards were extracted by liquid-liquid extraction. The method was validated over a linear concentration range of 1.0-1000.0 ng ml-1 for sildenafil and 0.5-500.0 ng ml-1 for N-desmethyl sildenafil with correlation coefficient (r2) ≥ 0.9998 for sildenafil and (r2) ≥ 0.9987 for N-desmethyl sildenafil. This method demonstrated intra and inter-day precision within 1.5 to 5.1 and 2.2 to 3.4% for sildenafil and within 1.3 to 3.1 and 2.8 to 4.3% for N-desmethyl sildenafil. This method demonstrated intra and inter-day accuracy for sildenafil within 97.3 to 98.3 and 96.7 to 97.2% and for N-desmethyl sildenafil within 95.3 to 96.3 and 95.0 to 97.2%. Both analytes were found to be stable throughout three freeze/thaw cycles, bench top and postoperative stability studies. This method was used successfully for the analysis of plasma samples following oral administration of 100 mg in 43 healthy Indian male human volunteers under fasting conditions.
More Related Videos
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
08:53Quantitative and Qualitative Method for Sphingomyelin by LC-MS Using Two Stable Isotopically Labeled Sphingomyelin Species
Published on: May 7, 2018