Assessing the influence of kernel selection on chest computed tomography image quality across varying dose levels
Eleftheria Gianko1,2, Micael Oliveira Diniz3,4, Walter Cifuentes Ramirez4
1Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
None:
Deep learning image reconstruction (DLIR) utilizes neural networks to generate high-quality computed tomography (CT) images. One commercially available DLIR software is TrueFidelity from GE Healthcare. The Standard kernel was the only available reconstruction kernel previously, but recently other kernels, including the Lung kernel, have been introduced by GE. This study aimed to evaluate the image quality of chest CT scans acquired at full-dose (FD, 2.5 mSv) and ultra-low-dose (ULD, 0.05 mSv) when reconstructed using TrueFidelity with both Standard and Lung kernels. Twenty-five patients underwent chest CT scans at Sahlgrenska University Hospital. The images were reconstructed and then evaluated by four radiologists in two different studies, one including ULD CT axial images and the other one the FDCT. Visual Grading Characteristics (VGC) analysis was applied, using the Standard kernel as reference and the area under the VGC curve (AUCVGC) for comparison. At FD, the Standard kernel yielded better results regarding the visualization of six structures and the general image quality. However, in ULD scans, the differences between kernels were not statistically significant. The FD images were mostly rated as acceptable, while ULD images were often rated as probably acceptable or unacceptable, especially for emphysema assessment. Overall, TrueFidelity seems to perform better with the Standard kernel than with the Lung kernel in FD protocols, but no reliable conclusions can be drawn for the ULD protocol.
More Related Videos
07:53Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT