Effects of Overcorrection on Mitigating Uncontrolled Tipping During Incisor Retraction Using Clear Aligners: Finite
Jianing Wang1,2, Niko Burger1,2, Bo Wang3,4
1Department of Biomedical Engineering and Science, Florida Institute of Technology, Melbourne, FL 32901.
None:
Uncontrolled tipping during incisor retraction with clear aligners continues to limit orthodontic treatment. Different countermeasures have been proposed to improve the predictability of aligners, such as power ridges and attachments, while their efficacy requires further investigation. This work investigated the biomechanics of the overcorrection in reducing the tipping angle and moment during incisor retraction with a clear aligner, through in vitro experiments and finite element analysis (FEA). Specifically, the influence of overcorrection angle (1 deg), retraction distance (0.15 mm), and the combination of both were assessed through in vitro experiments and the finite element simulation. Further computational simulations were conducted to inspect the mechanical performance of clear aligners with different overcorrection angles (from 0 deg to 1 deg and 2 deg) for a fixed retraction distance of 0.15 mm. As the overcorrection angle increased from 0 deg to 1 deg and 2 deg for the clear aligner with a retraction of 0.15 mm, the tipping angle of the incisor decreased from 0.29 deg to 0.25 deg and 0.21 deg, and the tipping moment at the tooth root decreased from 13.60 N·mm to 9.38 N·mm and 6.27 N·mm. However, the retraction force also decreased from 0.84 N to 0.73 N and 0.47 N, indicating a tradeoff between tipping control and retraction efficiency, likely due to increased counteractive moment and the decreased force exerted by the aligner on the tooth crown. In conclusion, this study presents both the benefits and limitations of overcorrection strategies in reducing the tipping angle and moment during incisor retraction using clear aligners, providing biomechanical insight for the optimal design of clear aligners for improving treatment outcomes.
More Related Videos
07:32Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Temperature Dependent Deformation
Stress Concentrations in Circular Shafts