Umbilical Coiling Index, Doppler Parameters, and Cord Blood Gas Analysis: Lack of Correlation in Uncomplicated Term
Zeynep Begum Celik1, Gulseren Dinc2, Suleyman Caner Karahan3
1Department of Obstetrics and Gynecology, Turhal State Hospital, Tokat 60300, Turkey.
Background/Objectives: In this study, we aimed to evaluate whether neonatal ischemia-modified albumin (IMA) and umbilical venous cord blood gas parameters are associated with antenatal markers of fetal well-being, including the umbilical coiling index (UCI) and umbilical artery (UA) and middle cerebral artery (MCA) Doppler indices. Methods: For this prospective observational study, sixty-five low-risk term pregnancies (≥37 weeks) were included. Prenatal ultrasound was used to measure the UCI and UA/MCA Doppler indices. At delivery, umbilical venous cord blood gas and serum IMA analyses were performed. Maternal and neonatal data (birth weight, 5 min Apgar score, NICU admission, sex, and delivery mode) were recorded, and correlations and group comparisons were performed (p < 0.05). Results: The UCI ranged from 0.210 to 0.471 coil/cm (mean 0.337). The UA and MCA Doppler indices were within the reference ranges. The UCI showed no significant correlation with umbilical venous blood gas values, IMA, UA/MCA Doppler indices, gestational age/weeks, or 5 min Apgar score. The UA S/D ratio and UA resistive index (RI) were negatively correlated with birth weight (p < 0.05). Umbilical venous pH was positively correlated with the 5 min Apgar score, whereas venous pCO2 was negatively correlated with the 5 min Apgar score (both p < 0.05). Newborns with venous pH < 7.32 had higher cesarean delivery rates and higher rooming-in rates. Newborns admitted to the NICU had higher mean UA systolic velocity/diastolic velocity (S/D) and UA pulsatility index (PI) and lower venous pH. Conclusions: In low-risk term pregnancies, the UCI was not associated with cord blood gas parameters, IMA, or UA/MCA Doppler indices. These results suggest that the UCI may have limited clinical utility as a predictor of early neonatal acidosis or oxidative stress in a strictly low-risk population.
Background/Objectives: In this study, we aimed to evaluate whether neonatal ischemia-modified albumin (IMA) and umbilical venous cord blood gas parameters are associated with antenatal markers of fetal well-being, including the umbilical coiling index (UCI) and umbilical artery (UA) and middle cerebral artery (MCA) Doppler indices. Methods: For this prospective observational study, sixty-five low-risk term pregnancies (≥37 weeks) were included. Prenatal ultrasound was used to measure the UCI and UA/MCA Doppler indices. At delivery, umbilical venous cord blood gas and serum IMA analyses were performed. Maternal and neonatal data (birth weight, 5 min Apgar score, NICU admission, sex, and delivery mode) were recorded, and correlations and group comparisons were performed (p < 0.05). Results: The UCI ranged from 0.210 to 0.471 coil/cm (mean 0.337). The UA and MCA Doppler indices were within the reference ranges. The UCI showed no significant correlation with umbilical venous blood gas values, IMA, UA/MCA Doppler indices, gestational age/weeks, or 5 min Apgar score. The UA S/D ratio and UA resistive index (RI) were negatively correlated with birth weight (p < 0.05). Umbilical venous pH was positively correlated with the 5 min Apgar score, whereas venous pCO2 was negatively correlated with the 5 min Apgar score (both p < 0.05). Newborns with venous pH < 7.32 had higher cesarean delivery rates and higher rooming-in rates. Newborns admitted to the NICU had higher mean UA systolic velocity/diastolic velocity (S/D) and UA pulsatility index (PI) and lower venous pH. Conclusions: In low-risk term pregnancies, the UCI was not associated with cord blood gas parameters, IMA, or UA/MCA Doppler indices. These results suggest that the UCI may have limited clinical utility as a predictor of early neonatal acidosis or oxidative stress in a strictly low-risk population.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Development of Blood Vessels
The initial formation of this system is facilitated by the small amount of yolk present in the ovum and yolk sac. Blood vessels originate from...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Ultrasonography
During an ultrasonography procedure, a handheld device called...