Related Experiment Video
Updated: May 11, 2026

Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
Published on: March 29, 2022
AstigMETRICS: An Automated Tool for Standardized Vector Metrics Tables and Group Comparisons in Refractive Surgery
Mathieu Gauvin1,2, Avi Wallerstein1,2
1Department of Ophthalmology and Visual Sciences, McGill University, Montreal, QC H4A 3S5, Canada.
Abstract:
Background/Objectives: Standardized reporting of astigmatism outcomes is essential for comparability, reproducibility, and interpretation of refractive surgery studies. Vectorial analyses based on established metrics are increasingly required by major journals, yet no freely available tool exists for generating publication-ready vector analysis tables with statistical comparisons. This study presents AstigMETRICS, a standalone application for automated calculation, formatting, and statistical comparison of standard vector metrics in refractive surgery. Methods: AstigMETRICS was developed in MATLAB and compiled as a standalone executable requiring no programming knowledge. The software accepts preoperative, intended, and postoperative astigmatism data in spreadsheet format for both refractive and corneal measurements. It calculates seven standard vector metrics following the Alpins method: the target-induced astigmatism (TIA), surgically induced astigmatism (SIA), difference vector (DV), correction index (CI), magnitude of error (ME), angle of error (AE), and index of success (IOS). Statistical comparisons are performed automatically using appropriate parametric or nonparametric tests for paired and unpaired study designs, with p-values and Cohen's d effect sizes reported. Results: AstigMETRICS generates standardized tables reporting the means, standard deviations, and clinically relevant proportions (percentage of eyes with an ME within ±0.50 D or ±1.00 D, and an AE within ±15°). Three simulated datasets were created to validate the software functionality across common surgical scenarios: a contralateral eye laser vision correction, toric phakic IOL implantation, and cataract surgery with toric IOLs. The output tables are displayed in standardized format and saved as high-resolution TIFF images suitable for publication. The software is freely available and a download link is provided in this article. Conclusions: AstigMETRICS enables clinicians and researchers to perform standardized, reproducible astigmatism vector analyses with built-in statistical comparisons. This freely available tool simplifies outcome reporting and improves methodological consistency in refractive surgery research.
Related Concept Videos
Trimmed Mean
Although certain measures of central tendency are not sensitive to outliers, there are alternative versions of the mean that get around the...
Automated Microbial Diagnostics

