Related Experiment Video
Updated: Mar 15, 2026

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Beyond One-Size-Fits-All: Precision Mechanical Ventilation in ARDS
Saif Azzam1, Karis Khattab2, Sarah Al Sharie3
1Faculty of Medicine, Yarmouk University, Irbid 21163, Jordan.
Abstract:
Acute respiratory distress syndrome (ARDS) has traditionally been managed with population-based, protocolized mechanical ventilation strategies designed to limit ventilator-induced lung injury. While these approaches have improved outcomes, they fail to account for the pronounced biological, mechanical, radiological, and temporal heterogeneity that characterizes ARDS. Accumulating evidence shows that patients differ markedly in functional lung size, recruitability, chest wall mechanics, inflammatory burden, and tolerance to ventilatory stress, making uniform ventilatory targets physiologically imprecise and, at times, harmful. This narrative review examines the evolution from conventional lung-protective ventilation toward a precision-based paradigm that aligns ventilatory support with individual patient physiology. We conceptualize ARDS not as a static syndrome but as a dynamic spectrum, viewing the injured lung as a heterogeneous mechanical system susceptible to regionally amplified stress and strain. Within this framework, we discuss key principles underlying precision ventilation, including functional lung size (the "baby lung"), driving pressure, mechanical power, patient-ventilator interaction, spontaneous breathing-associated injury, and the time-dependent evolution of lung mechanics. We synthesize current evidence supporting mechanical, biological, and radiological subphenotyping as complementary strategies to individualize ventilatory management, while critically appraising their current limitations. This review also evaluates bedside tools that may operationalize precision ventilation in clinical practice, including esophageal pressure monitoring, lung ultrasound, and electrical impedance tomography, and examines the role of artificial intelligence as a clinician-directed decision-support aid rather than a prescriptive substitute for physiological reasoning. Implications for clinical trial design, ethical considerations, and future directions toward predictive and adaptive ventilation strategies are also addressed. Precision mechanical ventilation represents a shift from rigid thresholds toward proportional, physiology-guided intervention across the disease trajectory. By integrating evolving lung mechanics, ventilatory load, and patient effort over time, this approach provides a coherent framework for safer and more effective mechanical ventilation in ARDS while preserving the core principles of lung protection.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Cardiopulmonary Resuscitation II: ACLS Airway Management

