Diagnostic Accuracy of Raman Spectroscopy for Oral Potentially Malignant Disorders: A Systematic Review and
Xiting Xiang1, Xing Li1,2, Zhihui Zhu1
1Division of Maxillofacial Surgery, Department of Stomatology, Peking Union Medical College Hospital, Chinese Academy of Medical Science & Peking Union Medical College, Beijing 100730, China.
Abstract:
Objective: The aim of this study was to summarize the accuracy and efficacy of Raman spectroscopy (RS) technology in identifying Oral Potentially Malignant Disorders (OPMDs). Methods: This systematic review was registered in PROSPERO (CRD420251124866). A literature search was conducted in databases including PubMed, Embase, and Web of Science from inception up to September 2025. The risk of bias of included studies was evaluated using the QUADAS-2 tool. Appropriate statistical techniques were applied to perform heterogeneity analysis, subgroup analyses, and calculation of pooled diagnostic efficacy indices. Results: A total of 12 studies involving 2810 samples were included. In the "OPMDs vs. Normal" group, RS achieved a pooled sensitivity of 0.84 (95% CI: 0.78-0.88), specificity of 0.90 (95% CI: 0.73-0.97), and AUC of 0.89 (95% CI: 0.86-0.91). In the "OPMDs vs. Oral squamous cell carcinoma (OSCC)" group, the pooled sensitivity was 0.89 (95% CI: 0.82-0.94), specificity was 0.91 (95% CI: 0.85-0.95), and AUC was 0.94 (95% CI: 0.91-0.96). Heterogeneity analysis revealed low heterogeneity in the "OPMDs vs. OSCC" group (I2 = 22.8%) and moderate heterogeneity in the "OPMDs vs. Normal oral mucosa" group (I2 = 58.9%). Subgroup analyses were performed: sample type exerted no significant impact on heterogeneity (p > 0.19), while Raman type (micro vs. fiber) showed potential to modulate diagnostic efficacy, micro-Raman had higher sensitivity (0.916 vs. 0.811), and fiber-Raman had better specificity (0.917 vs. 0.843). No significant publication bias was observed (Egger's p > 0.3). Conclusions: Raman spectroscopy is an effective and reliable tool for screening and differentiating OPMDs.
Related Concept Videos
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...