Related Experiment Video
Updated: Apr 28, 2026

Quantification of Site-specific Protein Lysine Acetylation and Succinylation Stoichiometry Using Data-independent Acquisition Mass Spectrometry
Published on: April 4, 2018
Rapid Analysis of Phytic Acid by Paper Spray Mass Spectrometry
Ping Guo1,2, Sijie Zhu1,2, Bo Chen1,2
1Key Laboratory of Phytochemical R&D of Hunan Province, Hunan Normal University, No. 36, Lushan Road, Changsha 410081, China.
Abstract:
Phytic acid (PA), owing to its strong acidity and multidentate metal-chelating properties, readily forms multiple adduct/complex ions in mass spectrometry and is prone to pronounced matrix effects, resulting in complicated spectra and compromised sensitivity and quantitative robustness, which poses a major challenge for rapid and accurate PA quantification. Herein, we developed a rapid quantitative method for PA based on trimethylsilyldiazomethane (TMSD) methyl-ester derivatization coupled with paper spray mass spectrometry (PS-MS). PA was derivatized with TMSD to yield the methylated product (PA-Me), and the derivative solution was purified via "post-derivatization nitrogen blow-down followed by water reconstitution", thereby markedly reducing background interference. In positive-ion mode, the stable sodium adduct ion [PA-Me+Na]+ (m/z 851.04) was used as the quantifier, enabling fast quantification with selected ion monitoring (SIM). PS-MS was performed with a 15 μL spotting volume and methanol/water (90/10, v/v, containing 0.1% formic acid) as the spray solvent, allowing rapid analysis without chromatographic separation. The method exhibited good linearity over 0.125-30 μg/mL (R2 ≥ 0.9965), with a limit of detection (LOD, S/N = 3) of 0.080 μg/mL and a limit of quantification (LOQ, S/N = 10) of 0.270 μg/mL. The intra-day and inter-day precision values were both < 10% (RSD), and recoveries ranged from 87.2% to 122.4%. This LC-free strategy features low solvent consumption and high analytical throughput, and was validated using rice bran protein and rice bran polysaccharide samples, providing technical support for rapid screening and quality control of PA in complex food/plant matrices.
More Related Videos
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
NMR and Mass Spectroscopy of Carboxylic Acids
While α protons of carboxylic acids absorb at 2–2.5 ppm, β protons absorb further upfield.
Carboxylic acids are easily identified by dissolving them in deuterium oxide, which results in a rapid exchange of the acidic protons with deuterium. This leads to the...
Mass Spectrometers
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation
For example,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...

