Short-Term Machine-Learning Calibration of PID Sensors for Ambient VOC OH Reactivity
Han Yang1,2,3, Wei Song1,2, Xiaoyang Wang1,2
1State Key Laboratory of Advanced Environmental Technology, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640, China.
Abstract:
Photoionization detector (PID) sensors are widely used for ambient Volatile organic compound (VOC) monitoring because they are inexpensive, flexible, and fast. However, PID outputs are strongly influenced by environmental conditions (especially temperature and relative humidity) and exhibit substantial inter-sensor variability, limiting their quantitative reliability. Here we present a rapid machine-learning calibration workflow that maps PID signals and meteorological covariates to a photochemically relevant reference metric, PTR-derived VOC OH reactivity (ROH,PTR, s-1), calculated from online PTR-ToF-MS VOC measurements weighted by OH reaction rate constants. Four MiniPID sensors were co-located with a PTR-ToF-MS and a thermohygrometer, and data were harmonized to 10-s resolution. Multiple regression models were evaluated, with ensemble methods (RF and XGBoost) providing the best overall performance. To ensure realistic generalization under temporal autocorrelation, validation used a time-aware split: models were trained on a contiguous 24-h co-location period and evaluated on subsequent days (out-of-time). In this out-of-time evaluation, XGBoost achieved strong agreement with ROH,PTR across sensors (Pearson's r = 0.85, R2 = 0.64, RMSE = 1.74 s-1), while substantially improving inter-sensor consistency. This short-duration calibration approach supports practical co-location-based harmonization of PID networks for high-temporal-resolution VOC reactivity monitoring in urban and industrial environments.
More Related Videos
07:12Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
06:21Author Spotlight: Understanding Processing of Olfactory and Spatial Information by Brain with Real-Time Behavioral Analysis
Published on: September 20, 2024
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
PID Controller
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...