Related Experiment Video
Updated: Mar 15, 2026

Characterization of SiN Integrated Optical Phased Arrays on a Wafer-Scale Test Station
Published on: April 1, 2020
Actor Placement Optimization in WSANs by the PSO-HC-DGA Hybrid System for Two-Zone Industrial Environments
Paboth Kraikritayakul1, Admir Barolli2, Shinji Sakamoto3
1Department of Information and Communication Engineering, Fukuoka Institute of Technology, Fukuoka 811-0295, Japan.
Abstract:
Wireless Sensor and Actor Networks (WSANs) are critical for industrial automation in the context of Industry 4.0, yet the optimal placement of actors to ensure connectivity and coverage remains an NP-hard problem. This study addresses the Actor Placement Problem (APP) in constrained, two-zone industrial environments. We propose a hybrid system, the PSO-HC-DGA hybrid system, which integrates Particle Swarm Optimization (PSO), Hill Climbing (HC), and the Distributed Genetic Algorithm (DGA). We evaluate four crossover methods (UNDX, SPX, BLX-α, and psBLX) combined with two actor replacement methods (RIWM and FC-RDVM) for small-, medium-, and large-scale scenarios. The simulation results demonstrate that psBLX is the most effective of the four crossover methods. In the small-scale scenario, it achieved better load balancing combined with RIWM, while in the medium-scale scenario, psBLX achieved full sensor coverage with RIWM and good load balancing with FC-RDVM. For the large-scale scenario, we compared the performance of the implemented hybrid system with that of a PSO system. The hybrid system showed 100% connectivity and achieved better sensor coverage than the PSO system. The Kruskal-Wallis test confirmed that the performance differences in load balancing were statistically significant. We conclude that the proposed hybrid system using psBLX enables robust and high-performance deployment in two-zone industrial WSANs.
Related Concept Videos
Hybrid Zones
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Distributed Loads: Problem Solving
Distributed Loads
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
PI Controller: Design
