Demystifying Venous Excess Ultrasound (VExUS): Image Acquisition and Interpretation
Published on: May 16, 2025
VExUS-ED: Early venous congestion is associated with clinical fluid overload in patients with sepsis
Sanne Ter Horst1, Jochem van Oosten2, Ranek Laros2
1Department of Internal Medicine, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.
Background:
Initial fluid resuscitation is central to sepsis management, yet excessive fluids may exceed a patient's fluid tolerance, increasing the risk of fluid overload and organ dysfunction. The Venous Excess Ultrasound (VExUS) score allows noninvasive bedside assessment of venous congestion, but its prevalence and predictive value in the emergency department (ED) are unclear.
Methods:
We analyzed prospectively collected data from the Acutelines data-biobank (University Medical Center Groningen, Netherlands). Adults with suspected sepsis requiring initial fluid resuscitation underwent VExUS assessments, including inferior vena cava and organ-specific Doppler measurements, within three hours of ED admission. The primary outcome was clinical fluid overload within 72 h, defined as positive fluid balance plus ≥10% weight gain, pulmonary edema on imaging, or loop diuretic use. Associations were analyzed using logistic and mixed-effects regression.
Results:
Among 103 patients, 34 (33%) developed clinical fluid overload. At ED admission, 75% had VExUS grade 0, 22% grade 1, and 3% grade ≥ 2. At baseline, VExUS>0 and abnormal hepatic venous Doppler flow were associated with fluid overload within 72 h (aOR 3.66, 95% CI 1.23-11.55; p = 0.022 and 4.20, 95% CI 1.21-16.38; p = 0.028, respectively). In repeated-measures analyses, VExUS>0 and abnormal intrarenal venous Doppler flow were associated with next-day fluid overload.
Conclusion:
In patients with suspected sepsis, mild venous congestion was independently associated with clinical fluid overload within 72 h. Abnormal hepatic and intrarenal flow patterns may provide additional information on venous congestion. Early, serial VExUS assessments may detect fluid intolerance and support individualized fluid management.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
07:59Bedside Ultrasound for Guiding Fluid Removal in Patients with Pulmonary Edema: The Reverse-FALLS Protocol
Published on: July 28, 2018
Related Concept Videos
Heart Failure III: Clinical Manifestations
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis IV: Nursing Management
Venous Thrombosis I: Introduction
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Varicose Veins I: Introduction