Wireless, non-invasive, high-resolution thrill sensor for continuous vascular access monitoring of hemodialysis

Yicong Wang1,2, Jie Wang3, Yuqi Tian1,2

  • 1Shanghai Key Laboratory of Digital Manufacture for Thin-Walled Structures, Shanghai Jiao Tong University, Shanghai, PR China.

Nature Communications
|March 16, 2026
PubMed

Hemodialysis is the primary life-sustaining therapy for patients with end-stage renal disease (ESRD). Diagnosing and monitoring the health condition of vascular access (VA) for hemodialysis involves the use of ultrasonic imaging and angiography. These infrequent tests cannot, however, identify signs of mild stenosis and sudden onset to facilitate early intervention. Hence, approximately 70% of hemodialysis patients experience VA failure each year, rendering dialysis difficult and posing life-threatening risks. Here, we report wireless, non-invasive thrill sensors incorporating high-resolution accelerometers designed to be conformally placed on VA skin for the continuous monitoring of VA thrill signals, which we tested in multi-platform validation including an in vitro benchtop system, canine models and patients (n = 9). Local measurements of VA thrill intensity via continuous wear demonstrated that a decrease in thrill intensity along the entire VA region is indicative of diminished VA function, while an abnormally heightened thrill intensity at a certain location along the VA indicates localized structural lesions. These thrill sensors may aid the early treatment of VA stenosis upon the transition from subjective thrill palpation to quantitative hemodynamic phenotyping.

Related Concept Videos

Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
2.8K
Continuous Renal Replacement Therapy01:30

Continuous Renal Replacement Therapy

Continuous Renal Replacement Therapy, also known as CRRT, is a procedural treatment for acute kidney injury (AKI) that gradually removes uremic toxins and fluids while maintaining acid-base balance and stabilizing electrolytes. It is particularly useful for hemodynamically unstable patients. Unlike intermittent hemodialysis, which is faster, CRRT provides a gentler approach over 24 hours, closely mimicking the function of natural kidneys. However, CRRT is not ideal for patients with...
1.7K
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this...
1.3K
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy01:26

Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy

Continuous Renal Replacement Therapy (CRRT) is an essential intervention for patients experiencing severe kidney dysfunction. This therapy offers a continuous mechanism for removing fluids and toxins from the bloodstream, leveraging the patient’s blood pressure to facilitate filtration through a specialized filter. This method contrasts with intermittent dialysis, providing a gentler and more consistent removal of waste products and excess fluid, which is particularly beneficial in...
315
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
1.6K
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.8K