Comparative evaluation of artifact extraction performance and usability in digital forensic tools: A study of Cellebrite UFED, MSAB XRY, and Magnet AXIOM
Related Experiment Video
Updated: May 1, 2026

Enhanced Genetic Analysis of Single Human Bioparticles Recovered by Simplified Micromanipulation from Forensic ‘Touch DNA’ Evidence
Published on: March 9, 2015
Sion Jenri Sinaga1, Mahmud Ali Asykar1, Hierony Manurung1
1Department of Computer Science, Universitas Indonesia, Depok, Jakarta, Indonesia.
Abstract:
The analysis of electronic evidence from smartphones is essential in modern criminal investigations. This study evaluates the performance of three widely used mobile forensic tools, Cellebrite UFED, MSAB XRY, and Magnet AXIOM, using logical extraction on two iOS and two Android devices, and assesses examiner-perceived usability through the System Usability Scale. On the iPhone 11 Pro, UFED (8539 artifacts) extracted more artifacts than XRY (6542 artifacts) and AXIOM (4220 artifacts). On the iPhone 13 Mini, total artifact counts were UFED (135,024 artifacts), XRY (173,140 artifacts), and AXIOM (355,671 artifacts), with the higher AXIOM volume largely influenced by cache-based and WebKit-related data, including web history (32,614 entries) and SMS artifacts (9101 entries). On the Xiaomi Redmi A3, extraction results were comparable across UFED (285 artifacts), XRY (280 artifacts), and AXIOM (329 artifacts). Greater variation was observed on the Samsung Galaxy A32, with UFED (28,214 artifacts), XRY (15,007 artifacts), and AXIOM (79,088 artifacts), primarily due to differences in artifact classification and provenance rather than disparities in access to core communication data. Usability evaluation showed mean System Usability Scale scores of AXIOM (71.0), UFED (69.2), and XRY (59.7). These findings indicate that artifact volume alone does not necessarily reflect evidentiary value and that forensic tool selection should balance decoding capability, artifact provenance, and usability to ensure reliable and defensible digital evidence analysis.
More Related Videos
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Mass Analyzers: Overview

