Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
The Influence of Temperature on Stationary Phase Retention in Countercurrent Chromatography: Integrating Experiment
Peishan Zhao1, Mengjiao Yuan1, Yan Liu2
1Shanghai Frontiers Science Center of Optogenetic Techniques For Cell Metabolism, East China University of Science and Technology, Shanghai, China.
None:
The selection of a biphasic solvent system is the first and most important step for a successful countercurrent chromatography (CCC) separation. The partitioning coefficient of targets and their related impurities on one side, and the stationary phase retention on the other, are among the parameters used for solvent system selection. At constant temperature, the stationary phase retention of a selected solvent system in any CCC instrument is dominated by the rule of Du's plot, which describes the correlation between stationary phase retention and flow rate. In a biphasic liquid system, physico-chemical properties such as density, viscosity, and interfacial tension between two phases are temperature dependent. In this article, the effect of temperature on the retention of several typical solvent systems was investigated using a high-speed CCC (HSCCC) instrument. The results showed that temperature changes could induce density, viscosity, and interfacial tension variation of the biphasic system with consequent changes in the system's hydrodynamic behavior. As the temperature increased, the density and viscosity of the selected solvent system decreased. This led to a variation in the interfacial tension between two phases depending on the solvent system composition. The stationary phase retention increased when the temperature increased for the tested solvent systems. Based on the obtained results, an improved Du's plot was suggested, accounting for the contribution of operating temperature. The prospect of this article provides hands-on strategies for the development of high-performance separation method for HSCCC.
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Chromatographic Methods: Terminology
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Principles Of Column Chromatography