Related Experiment Video
Updated: Mar 18, 2026

Predictive Measurement for Windlass Change in Length and Selected Treatment Outcomes in Chronic Plantar Fasciitis
Published on: March 1, 2024
Diagnostic Performance of Large Language Models in Musculoskeletal Ultrasound: A Comparative Evaluation of
Ilknur Akkus1, Gulnihal Deniz2
1Department of Physical Medicine and Rehabilitation, Elazıg Fethi Sekin City Hospital, Elazıg, Turkey. drilknurakkus@gmail.com.
Abstract:
Recent advances in large language models (LLMs) have prompted growing interest in their potential to assist with musculoskeletal ultrasound interpretation. However, evidence regarding their diagnostic performance in plantar fasciitis remains scarce. This study evaluated the accuracy of ChatGPT-5.1 and Gemini in classifying plantar fasciitis on longitudinal ultrasound images, using a board-certified physiatrist's assessment as the reference standard. In this prospective diagnostic accuracy study, 80 anonymized plantar fascia ultrasound images were analyzed independently by ChatGPT-5.1 and Gemini using standardized interpretive prompts. Images were classified as normal or pathological based on established criteria, including fascial thickness ≥ 4 mm, hypoechogenicity, and disturbance of fibrillar structure. Diagnostic metrics (sensitivity, specificity, predictive values, accuracy, F1-score, and Cohen's κ) were calculated. Comparative performance was assessed using McNemar's test. ChatGPT-5.1 demonstrated a balanced diagnostic profile, achieving a sensitivity of 67.6%, specificity of 97.7%, and overall accuracy of 83.8%. In contrast, Gemini exhibited maximal sensitivity (100%) but substantially reduced specificity (37.2%), yielding an overall accuracy of 66.3%. Confusion matrices revealed divergent error structures: ChatGPT-5.1 produced few false positives (n = 1), whereas Gemini generated many (n = 27). Agreement with the reference standard was substantial for ChatGPT-5.1 (κ = 0.666) and fair for Gemini (κ = 0.354). McNemar's test showed a significant difference in paired classification decisions between the models (p = 0.035). Precision-recall analysis indicated a more favorable precision-recall balance for ChatGPT-5.1. ChatGPT-5.1 showed high specificity, whereas Gemini demonstrated higher sensitivity, indicating different diagnostic operating characteristics rather than overall superiority. These patterns suggest potential screening-oriented use for Gemini and confirmatory use for ChatGPT-5.1. The findings support the feasibility of LLM-assisted musculoskeletal ultrasound interpretation and highlight the need for multicenter validation and integration strategies based on complementary model characteristics.

