Related Experiment Video
Updated: Mar 19, 2026

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Revisiting Light's criteria: a validated blood-free triple combination matches diagnostic accuracy in over 7000
José M Porcel1, Laura Porcel2, Rosa Palma1
1Pleural Medicine and Clinical Ultrasound Unit, Department of Internal Medicine, Arnau de Vilanova University Hospital, IRBLleida, Lleida, Spain.
Background:
Light's criteria remain the standard for distinguishing exudative from transudative pleural effusions, but require serum sampling and lack specificity. We assessed whether a pleural fluid-only approach could match the diagnostic accuracy.
Methods:
We analysed 7280 diagnostic thoracenteses from a single centre, divided into derivation (n=5000) and validation (n=2280) cohorts. We compared Light's criteria with a triple (protein >3 g·dL-1, lactate dehydrogenase (LDH) >250 IU·L-1 or cholesterol >55 mg·dL-1) and a double (LDH >250 IU·L-1 or cholesterol >55 mg·dL-1) combination using sensitivity, specificity, likelihood ratios and area under the curve (AUC). AUCs were assessed using the DeLong method with multiple imputations from a mixed model. McNemar's test examined discordant classifications.
Results:
The triple combination showed no significant AUC difference versus Light's criteria in either cohort and had equivalent sensitivity (99% versus 98% in derivation; both 98% in validation). In the derivation cohort, McNemar's test showed a small but statistically significant excess of false negative exudates with the triple combination (p<0.001), whereas no significant difference was found in the validation cohort (p=0.241). The triple combination correctly reclassified 19-20% of transudates misclassified by Light's criteria, while the reverse occurred in 11-14%. The double combination yielded the highest AUCs but missed more exudates, limiting its clinical safety.
Conclusion:
A pleural fluid-only triple combination matches Light's criteria in diagnostic accuracy, avoids serum sampling and improves specificity with minimal sensitivity loss in one cohort. This approach may be a practical alternative for the initial classification of pleural effusion when blood sampling is unavailable or undesirable.
More Related Videos
09:00Author Spotlight: Validation of SICOLE-R for Assessing Cognitive and Reading Skills in Spanish-Speaking Children and Its Role in Personalized Education
Published on: August 16, 2024
09:37Combining Reflectance Confocal Microscopy with Optical Coherence Tomography for Noninvasive Diagnosis of Skin Cancers via Image Acquisition
Published on: August 18, 2022
Related Concept Videos
Receiver Operating Characteristic Plot
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Automated Microbial Diagnostics