Related Experiment Video
Updated: Mar 20, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Text-guided automatic segmentation of clinical target volume in rectal cancer radiotherapy
Huijuan Peng1, Yuting Liang1, Shangyan Wei1
1National Cancer Center/National Clinical Research Center for Cancer Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China.
None:
Objective.Current automatic segmentation models in radiotherapy, which are predominantly unimodal and image-based, have limited generalizability due to boundary ambiguity and the lack of guideline integration. This study proposes a text-guided segmentation network, termed (TG-SegNet), for the automatic delineation of clinical target volumes (CTVs) in rectal cancer radiotherapy.Approach.Data from 567 preoperative patients with rectal cancer were retrospectively collected. Text prompts contained (i) patient case information (age, sex, tumor stage, tumor location, position) and (ii) guideline-derived descriptions indicating which CTV subsites should be included. TG-SegNet integrates computed tomography-derived visual features with structured clinical text prompts encoded by PubMedBERT, fused via cross-attention and fine-grained fusion. The model was trained on 452 patients and tested on 115. Its performance was compared with that of nnU-Net and two ablated variants (TG-SegNet without text prompts and TG-SegNet with simplified fusion). The evaluation comprised quantitative metrics, including dice similarity coefficient (DSC), 95% Hausdorff distance (HD95), mean surface distance (MSD), surface DSC (S-DSC), and average path length (APL), along with blinded expert scoring and an efficiency analysis. In additional analyses, we conducted text-prompt and module ablations.Main results.TG-SegNet achieved the best performance across all quantitative metrics: DSC 0.927 ± 0.022, HD95 7.01 ± 6.05 mm, MSD 1.94 ± 1.08 mm, S-DSC 0.799 ± 0.074, and APL 7372 ± 4452 (allp< 0.01). In clinical evaluation, TG-SegNet significantly improved target coverage, guideline adherence, and overall clinical acceptability compared with nnU-Net and ablations (p< 0.05), with boundary appropriateness comparable to nnU-Net. TG-SegNet had the shortest correction time (3.39 ± 1.10 min), corresponding to 82.1% time savings versus manual delineation. Text-prompt ablations suggested that the CTV-subsite prompt component contributed more to performance. Module ablations showed that both cross-attention and fine-grained fusion were beneficial.Significance.By integrating clinical semantics with imaging, TG-SegNet demonstrated superior accuracy, efficiency, and clinical acceptability over nnU-Net and ablated models, highlighting its potential for clinical translation.