Related Experiment Video
Updated: Mar 20, 2026

Author Spotlight: Advancing Place-Based Biochar Production for Ecosystem Restoration and Soil Health
Published on: April 5, 2024
Bioethanol fireplaces as indoor pollution sources: The role of burner design and fuel type
Estela D Vicente1, Yago Cipoli1, Isabella Charres1
1Department of Environment and Planning, Centre for Environmental and Marine Studies, University of Aveiro, Aveiro 3810-193, Portugal.
Abstract:
Bioethanol fireplaces are marketed as clean and decorative heating alternatives. However, their impact on indoor air quality (IAQ) remains poorly characterised. This study investigates the indoor levels of gaseous and particulate pollutants using a bioethanol fireplace operated under realistic conditions. Two types of bioethanol fuels and two burner designs, a single-chambered (SC) and a double-chambered (DC), were tested under minimal ventilation. Concentrations of CO, NO, NO2, CO2, NH3, N2O, C2H6O, total volatile organic compounds (TVOCs), and carbonyl compounds were measured, while particulate matter (PM10) was characterised chemically and toxicologically. Combustion of both fuels led to substantial increases in indoor pollutant concentrations compared to background levels. Indoors, maximum average CO levels reached 5.67 µg m-3, NO 0.33 µg m-3, NO2 0.85 µg m-3 and TVOCs exceeded 1400 µg m-3. Acetaldehyde and formaldehyde were the dominant carbonyls, with the latter frequently surpassing the WHO guideline value along with NO2. Compared with traditional wood combustion, bioethanol combustion produced relatively higher indoor concentrations of nitrogen oxides, acetaldehyde, and formaldehyde. Average PM10 concentrations ranged from 31.5 to 173 µg m-3, with higher indoor concentrations for the DC burner and Fuel 2. PM10 samples were enriched in bromine, ammonium and nitrate during combustion, and exhibited elevated oxidative potential. Differences in indoor pollutant levels and oxidative potential were observed depending on the burner design, fuel type and initial fuel load. These results demonstrate that flueless bioethanol fireplaces can markedly deteriorate IAQ, underscoring the need for performance standards, improved fuel formulations, and adequate ventilation to mitigate exposure risks associated with their use.
Related Concept Videos
Flame Photometry: Overview
Biofuels
Bioreactor Design and Operational System
Enthalpy and Heat of Reaction
Bioreactor Controls-II
Combustion Energy: A Measure of Stability in Alkanes and Cycloalkanes
Alkanes undergo combustion in the presence of excess oxygen and high-temperature conditions to give carbon dioxide and water. A combustion reaction is the energy source in natural gas, liquified...

