Related Experiment Video
Updated: Jul 5, 2026

Facile Preparation of 4-Substituted Quinazoline Derivatives
Published on: February 15, 2016
Ground truth data set of Gas Chromatography Mass Spectrometry (GCMS) analysed synthesised methylamphetamine
Roberto Puch-Solis1, Farhan Tanvir Santo1, Jonathan Miller1
1Leverhulme Research Centre for Forensic Science, University of Dundee, Nethergate, Dundee DD1 4HN, UK.
Abstract:
Controlled substances are typically subjected to chemical analysis for the purpose of identifying them and, in certain instances, determining their purity using a comprehensive characterisation. This requires the analysis of chemical impurities that may be present in a drug sample due to the synthesis process. This process, known as impurity or drug profiling, can be applied to drugs that are chemically synthesised and/or subsequently chemically modified. The profiling of impurities can offer insights into the synthetic methods employed and, at times, the initial chemicals utilised. Our article focuses on data obtained from the repetitive synthesis (n = 152) of methylamphetamine using five distinct synthetic routes or pathways: Rosenmund Reduction, Birch Reduction, Moscow route, Hypophosphorous route and Emde route. Each sample has been analysed using Gas Chromatography Mass Spectrometry (GCMS) producing a chromatogram, which is presented in various formats. A template for publishing GCMS data is given in [1] which provides a systematic and robust method to organise GCMS data that is amenable for automated handling by data scientists and accessible to practitioners. The template has been previously applied to MDMA [2]. This paper is the third in the series and is addressing the impurity of methylamphetamine samples using the five pathways listed above. The data can be used for methylamphetamine characterisation according to the synthesis method used, the automated detection of the synthetic method using machine learning, and for training purposes.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.