Characterisation of Antisense Oligonucleotides by Ion-Pair Reversed-Phase UHPLC-HRMS: Method development using Design
Antonio Triolo1, Fabiana Tavani1, Prisca Barnini2
1Laboratory of Advanced Analytics, Menarini Ricerche Spa, Florence, Italy.
None:
The quality control of therapeutic antisense oligonucleotides (ASOs) poses significant analytical challenges due to the complexity of their synthesis and degradation processes and the need to ensure the safety and efficacy of active pharmaceutical ingredients (APIs). In this study, an ion-pair reversed-phase ultra-high-performance liquid chromatography-high-resolution mass spectrometry (IP-RP-UHPLC-HRMS) method based on Orbitrap technology was developed using fomivirsen (FMV) and tofersen (TFR) as model compounds. A preliminary scouting phase was dedicated to selecting the type of ion-pair reagent and MS parameters settings (sheath gas, auxiliary gas temperature and S-lens), based on MS spectrum quality (charge state distribution, presence of adducts and in-source fragments), MS signal height and chromatographic peak shape. Design of Experiments (DoE) through response surface methodology was employed to evaluate the effects of the following factors in depth: concentration of the ion pair reagent N,N-diisopropylethylamine and of 1,1,1,3,3,3-hexafluoroisopropanol in the mobile phase and elution gradient slope. The responses selected were the UV height and baseline width of the main peak of the APIs, as well as the resolutions between selected impurities from their extracted MS chromatograms. A multidimensional space (sweet spot) was defined in which the response requirements were met, enabling multicriteria optimisation and the set-up of two distinct IP-RP-UHPLC-MS methods for FMV and TFR characterisation, based on shared mobile phase components and MS parameters. All four FMV impurities and 13 out of 15 detected TFR impurities were identified above 0.1%. DoE approach has been demonstrated to be an effective tool for achieving a balance between sensitivity and selectivity in the analysis of ASOs, identifying optimum conditions tailored to oligonucleotide type and ion-pair agent and paving the way for more structured development processes, as recommended by recent regulatory requirements for pharmaceutical analytical procedure development.
More Related Videos
11:37Protocol for the Solid-phase Synthesis of Oligomers of RNA Containing a 2'-O-thiophenylmethyl Modification and Characterization via Circular Dichroism
Published on: July 28, 2017
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
Ion-Exchange Chromatography
High-Resolution Mass Spectrometry (HRMS)
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry