Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

2.0K
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
2.0K
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

1.8K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.8K
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

2.9K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2.9K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

2.5K
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
2.5K
Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

8.8K
Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
8.8K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

2.0K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
2.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Loss of Ambp ameliorates steatosis progression by activating PPARα signaling in zebrafish.

The FEBS journal·2026
Same author

Glutathione metabolism-linked ferroptosis in human seminoma: a spatial multi-omics mapping study.

Redox biology·2026
Same author

BMI-based metabolic syndrome Z-score and gastrointestinal cancers: A cohort study.

Medicine·2026
Same author

Towards clinical-level interpretation of dental panoramic radiography using an instance-guided vision-language model.

Nature biomedical engineering·2026
Same author

A near-room temperature solid composite electrolyte enabled by lithiated sulfonated covalent organic frameworks.

Chemical communications (Cambridge, England)·2026
Same author

Efficacy and safety of acupuncture for post-stroke spasticity: a study protocol for a randomized controlled trial.

Frontiers in neurology·2026
Same journal

Structural Hairpin Anchoring-Mediated TtAgo Activity Regulation for Programmable Biosensing.

Analytical chemistry·2026
Same journal

Digital Revitalization of a Legacy Linear Ion Trap System.

Analytical chemistry·2026
Same journal

An Interface-Regulated Electrochemical Biosensing Platform Based on the Cascade Amplification of Primer Exchange Reaction and CRISPR/Cas12a for Noninvasive Bladder Cancer Diagnosis.

Analytical chemistry·2026
Same journal

Spatially Resolved Diffusion NMR for Structurally Heterogeneous Materials.

Analytical chemistry·2026
Same journal

Direct Whole-Blood Multiplexing of Small Molecules via a Micelle-Enhanced Chemiluminescent Paper Sensor with Mesoporous Silica Membrane.

Analytical chemistry·2026
Same journal

Modeling the Effects of Short-Range Randomness in Packed Sphere Beds.

Analytical chemistry·2026
See all related articles

Related Experiment Video

Updated: Mar 21, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
08:40

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

Published on: January 20, 2022

5.0K

Fourier Deconvolution Multiplexing Boosts Ion Throughput in Pinhole-Interfaced GC-IMS/MS for Synchronous Peak

Xiuqing Zheng1, Jianna Yu1, Mengting Huang1

  • 1College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China.

Analytical Chemistry
|March 20, 2026
PubMed
Summary
This summary is machine-generated.

This study introduces an integrated gas chromatography-ion mobility spectrometry/mass spectrometry (GC-IMS/MS) platform with Fourier deconvolution, significantly improving peak identification and sensitivity for food safety and environmental analysis.

More Related Videos

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
10:17

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry

Published on: April 23, 2019

10.4K
Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
09:38

Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

Published on: November 26, 2013

14.7K

Related Experiment Videos

Last Updated: Mar 21, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
08:40

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

Published on: January 20, 2022

5.0K
High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
10:17

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry

Published on: April 23, 2019

10.4K
Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
09:38

Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

Published on: November 26, 2013

14.7K

Area of Science:

  • Analytical Chemistry
  • Spectrometry
  • Separation Science

Background:

  • Gas chromatography-ion mobility spectrometry (GC-IMS) is valuable for rapid analysis in food safety, environmental monitoring, and security.
  • A key challenge in GC-IMS is accurate peak identification due to limited reference databases.
  • Conventional GC-IMS/MS systems suffer from low ion utilization efficiency and detector sensitivity imbalance.

Purpose of the Study:

  • To develop and validate an integrated GC-IMS/MS platform to overcome limitations of existing systems.
  • To enhance ion utilization efficiency and detector sensitivity for improved analytical performance.
  • To provide a robust tool for precise compound identification and high-throughput screening.

Main Methods:

  • Development of an integrated GC-IMS/MS platform incorporating Fourier deconvolution (FD) technology.
  • Implementation of a novel pinhole IMS-MS interface to improve ion transmission.
  • Utilizing FD multiplexing to increase the ion gate duty cycle significantly.

Main Results:

  • Achieved precise synchronization between IMS drift peaks and MS spectral data for six volatile organic compounds.
  • Demonstrated an average ion transmission enhancement exceeding 110-fold compared to conventional systems.
  • Exhibited excellent quantitative performance with linearity (R² > 0.995) and ng/mL detection limits.
  • Successfully applied the platform to complex samples like tobacco, tea, and apricot flavoring extracts.

Conclusions:

  • The developed GC-IMS/MS platform effectively addresses peak identification challenges in GC-IMS.
  • The system offers precise compound identification and high-throughput nontargeted screening capabilities.
  • This advancement holds significant potential for applications in food safety, environmental monitoring, and security screening.