Wagner-Nelson Analysis to Create "True" Gastric Emptying Curves in 13C Breath Testing: A Pharmacokinetics-Based
Masaki Sanaka1,2, Takatsugu Yamamoto3
1Department of Medical Pharmacy, Faculty of Pharmaceutical Sciences, Josai International University, Chiba, Japan, sanaka@jiu.ac.jp.
Background:
Breath testing to study gastric emptying (GE) has been criticized that its conventional analysis provides only an overall GE velocity (half-emptying time) that is far off from the scintigraphic scale, and it cannot give a whole pattern of time-GE curve comparable to what the scintigraphy expresses ("true" GE).
Summary:
GE breath tests (GEBT) approximate absorption of the 13C-marker (GE) from pulmonary 13CO2elimination. The Wagner-Nelson (WN) method has long been used for accurately describing drug absorption based on urinary elimination. Then, GEBT with WN analysis has been reported to provide a time-GE curve comparable to the "true" GE of both solid and liquid meals. To handle the WN method properly, attention should be directed to the two assumptions on which the WN method relies; one-compartment model and first-order kinetics. The former is responsible for the slight overestimation of the "true" GE of liquids. The latter is associated with the necessity of longer sampling time, more than 6 h, which could reduce the convenience of GEBT, but a recent study has proposed how to address this problem.
Key Messages:
The WN method gives a complete picture of the time-resolved GE curve (and not just lag phase or half-time values) equivalent to what nuclear scintigraphic studies do.
More Related Videos
05:50Author Spotlight: Point-of-Care Ultrasound for Gastric Content Assessment and Risk Stratification in Perioperative Care
Published on: September 22, 2023
09:29Fabrication and Implantation of Miniature Dual-element Strain Gages for Measuring In Vivo Gastrointestinal Contractions in Rodents.
Published on: September 18, 2014
Related Concept Videos
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Gastric Emptying
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Gastric Phase of Digestion
When food enters the stomach, it stretches the stomach walls and activates stretch receptors. This triggers local reflexes of the enteric nervous system, mediated through the myenteric plexus. These...