Related Experiment Video
Updated: Mar 23, 2026

Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
Hydroxypropyl-β-cyclodextrin-assisted Acetonitrile Field-amplified Stacking in Capillary Electrophoresis Enabling
Haixia Deng1,2, Weimin Gao1,2, Yuping Liu1,2
1School of Pharmaceutical Sciences and Yunnan Key Laboratory of Pharmacology for Natural Products, Kunming Medical University, Kunming, China.
Abstract:
Amlodipine besylate, a third-generation dihydropyridine calcium channel modulator, is routinely prescribed as a racemic mixture in the clinical management of arterial hypertension and ischemic chest pain. Among its enantiomeric pair, (S)-amlodipine is the pharmacologically active form and is primarily responsible for the antihypertensive effect. Given that both (R)- and (S)-amlodipine circulate at extremely low concentrations following oral administration, a highly sensitive analytical method is required for enantioselective monitoring. In this study, we developed a simple, sensitive, and cost-effective capillary electrophoresis (CE) method for clinical application, which integrates hydroxypropyl-β-cyclodextrin-mediated chiral recognition with acetonitrile-driven field-amplified sample stacking. Chiral resolution of trace amlodipine (AML) present in human plasma samples was performed in an uncoated bare fused silica capillary (effective length 31.2 cm, internal diameter 75 µm), thermostated at 25°C and operated with an imposed potential of 15 kV. The running buffer consisted of borate (6.25 mM) and phosphate (25 mM), adjusted to pH 2.5, containing 30 mg/mL hydroxypropyl-β-cyclodextrin, and ultraviolet monitoring was conducted at 200 nm. This assay was fully validated for the quantitative measurement of each AML enantiomer in plasma. For (R)- and (S)-amlodipine, linear calibration was achieved across the range 0.2475-19.80 ng/mL and met the commonly accepted bioanalytical criteria. Comparative pharmacokinetic evaluation demonstrated no statistically significant differences between the concentration-time profiles obtained with the proposed CE method and those generated by a reference liquid chromatography-tandem mass spectrometry assay, confirming the accuracy and reliability of the developed procedure for routine therapeutic drug monitoring.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
11:44Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
Published on: January 19, 2022
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...