Related Experiment Video
Updated: Mar 24, 2026

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
A temperature self-calibrated MEMS gyroscope with 0.007°/h/K bias drift coefficient using real-time parametric
Yaojie Shen1,2, Xudong Zheng3, Chen Fang1
1Key Laboratory of Micro-nano Satellite Research of Zhejiang Province, School of Aeronautics and Astronautics, Zhejiang University, Hangzhou, P. R. China.
None:
Both mechanical and electrical errors contribute to the zero-rate output (ZRO) of MEMS gyroscopes, which mainly include quadrature error leakage into the in-phase channel and in-phase errors originating from force misalignment, electrical feedthrough, and damping mismatch between the gyroscope drive mode and sense mode. A new self-calibration control scheme for the gyroscope's ZRO based on parametric excitation (PE) quality factor control and mode matching is proposed in this paper, featuring the advantages of simultaneously suppressing the impact of electrical feedthrough, force misalignment and real-time compensating for the effective sense mode quality factor drift due to temperature variations, providing a practical solution to achieve low temperature sensitivity of ZRO for high-performance MEMS gyroscopes. As a result, the bias instability (BI) decreases from 0.295 °/h to 0.156 °/h over the temperature range of -20°C to 50 °C, while the rate random walk (RRW) decreases from 0.0038 °/√(h3) to 0.0014 °/√(h3), a 2.7-fold reduction. The temperature coefficient of bias drift with self-calibration decreases from 0.864 °/h/K to 0.007 °/h/K with a reduction of 122 times, which is the best value reported publicly to date.
Related Concept Videos
Gyroscope: Precession
Biasing of FET
In an N-channel JFET, the structure consists of N-type material forming the channel on a P-type substrate, with the...
Gyroscope
Biasing of Metal-Semiconductor Junctions
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Magnetic Damping