How to Manage the Humidity of Biological Samples to Reduce Interference on Chemical Sensors
Ana Maria Tischer1, Beatrice Julia Lotesoriere1, Laura Capelli1
1Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy.
Abstract:
High humidity in biological gas samples (e.g., exhaled breath or headspace from biological fluids) can mask the detection of volatile compounds at low concentrations, reducing sensitivity and stability of chemical sensors. Though progress has been made in developing new sensor systems, unless humidity interference is well addressed, chemical sensors cannot be validated for clinical use. This review aims to provide a practical guide for researchers working in the field of chemical sensors for clinical diagnosis, where managing sample humidity is particularly critical to ensure good diagnostic accuracy. In this review, we analyzed the mechanisms of humidity interference with chemical sensors and discussed sampling strategies to mitigate it in biological sample analysis. Building on dehumidification strategies developed for well-established analytical techniques, we translate these insights to evaluate their possible application to chemical sensor analysis. We critically reviewed five sampling strategies to manage humidity: condensation, permeation, desiccants, dry dilution, and water trap. The operating principles, applications, as well as the advantages, limitations, and contamination risks of each technique are discussed. In practice, each method entails tradeoffs between residual humidity and analyte recovery, requiring careful selection depending on the application. Thoughtfully implemented, these strategies convert humidity from a confounder into a controlled variable, enabling safer and more reliable measurements.
Related Concept Videos
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Preparation of Samples for Electron Microscopy
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...