Design and Optimization of the Interface of Gas Chromatography and Photoionization Ion Mobility Spectrometry Aided by
Peiran Song1,2,3, Huaiwen Cang2,3, Zhihao Zhang2,3
1College of Mechanical Engineering, Dalian Jiaotong University, Dalian 116028, People's Republic of China.
Abstract:
Photoionization ion mobility spectrometry (PIMS) hyphenated with gas chromatography (GC) exhibits outstanding selectivity and high sensitivity in the detection of trace volatile organic compounds (VOCs). Its analytical performance is considerably affected by the interface between the GC and the ionization chamber of the PIMS. The sensitivity of the PIMS is reliant on the overlap of photoionization optical fields with the effluent from the GC, which is also affected by the gas flow in the ion mobility spectrometer. In this work, a computational model based on multiphysics dynamic convolution has been developed to evaluate the spatial concentration distribution of sample gas on the photoionization yield of PIMS. The simulation results indicate that lateral injection of GC capillary column into the gas flow of the ion mobility spectrometer could enhance the sensitivity by increasing the overlap of effluent and the VUV light in the ionization region of PIMS. The optimal capillary insert depth was increased when decreasing the carrier gas flow rate, which was confirmed by numerical simulations and experimental measurements. The optimal insert depth was 7.5 mm (the central axis of the ionization source) under conditions of a carrier gas flow rate of 15 mL·min-1, the limit of detection for aromatic compounds was reached 2.5 ppbv, achieving a 4-fold improvement of sensitivity over zero insertion. The GC-PIMS was tested to assess the VOCs emissions from spray-coated surfaces, and trace levels of toluene (45 μg·m-3) and xylene (60 μg·m-3) were still detectable even 14 days later, which highlights the potential of the GC-PIMS apparatus for monitoring trace environmental pollutants.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Ion-Exchange Chromatography