Related Experiment Video
Updated: Mar 27, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Reconstruction of an Unguarded Tricuspid Orifice Using a Simplified Sliding Plasty Technique
Maurits Zegel1, Elke S Hoendermis2, Joost P van Melle2
1Department of Pediatric and Congenital Cardiothoracic Surgery, Center for Congenital Heart Disease, University Medical Center Groningen, University of Groningen, 9700 RB Groningen, The Netherlands.
Abstract:
Unguarded tricuspid orifice is a rare anomaly of the tricuspid valve characterized by complete absence of tricuspid valve tissue and chordae on a proportion of the annulus. Management strategies vary widely. We report a case of successful repair of an unguarded tricuspid orifice with a simplified technique. A 35-year-old male presented with severe tricuspid regurgitation and right ventricular volume overload. Intraoperative inspection of the valve revealed an unguarded tricuspid orifice. For repair, sliding plasty of the anterior and posterior leaflets was performed, followed by ring annuloplasty and commissuroplasty. Postoperative, echocardiogram showed minimal residual tricuspid regurgitation and significantly improved right ventricular dimensions. This case highlights the possibility of successful repair of an unguarded tricuspid orifice. If feasible, repair can be a good choice.