Staged domain adaptation with transformer for bearing remaining useful life prediction
Lixiao Cao1, Zijian Lu1, Zong Meng1
1Key Laboratory of Measurement Technology and Instrumentation of Hebei Province, Yanshan University, Qinhuangdao, 066004, Hebei Province, China; Key Laboratory of Intelligent Control and Neural Information Processing, Ministry of Education, Yanshan University, Qinhuangdao 066004, Hebei Province, China.
Abstract:
Accurate prediction of Remaining Useful Life (RUL) is essential to optimize operational efficiency in engineered maintenance systems. Conventional transfer learning approaches often suffer from negative transfer when applied across the entire equipment lifecycle, primarily due to stage-specific distribution shifts. Forcing global alignment between early-stage normal data and late-stage fault data distorts the degradation trajectory, leading to significant prediction errors. Additionally, health indicators are difficult to accurately model in the bearing degradation process. To address this, we propose a Stage-Aware Adversarial Domain Adaptation Framework. Unlike conventional methods that treat the lifecycle as homogeneous, our approach introduces a theoretically grounded staging mechanism driven by CAE-derived Health Indicators (HI). By explicitly decoupling domain alignment into distinct degradation phases, we ensure feature alignment occurs only within semantically consistent operational regimes. Furthermore, domain adversarial neural networks (DANN) and maximum mean discrepancy (MMD) enhance cross-phase adaptability. The experimental results have been validated with two datasets, and show an improvement in prediction accuracy above 10% compared to both traditional and transfer learning methods, offering new methods for domain alignment for transfer learning in this field.
Related Concept Videos
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Bearings: Problem Solving
Transformers with Off-Nominal Turns Ratios
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...