Related Experiment Video
Updated: Jun 3, 2026

Manual Muscle Testing: A Method of Measuring Extremity Muscle Strength Applied to Critically Ill Patients
Published on: April 12, 2011
Medical device errors in intensive care units and patient safety: a systematic review
Zerin Ziaudeen1, Selvam Jesiah1, Anusha Dakshinamoorthi2
1Sri Ramachandra Faculty of Management Sciences, Sri Ramachandra Institute of Higher Education and Research (Deemed to be University), Chennai, India.
Introduction:
Medical device errors in Intensive Care Units (ICUs) position a critical threat to patient safety due to the complexity of devices, high patient alertness, and demanding clinical situations. Despite rising support on medical technologies, evidence on the nature of causes and prevention of device-oriented errors in ICUs remains fragmented.
Methods:
The PRISMA guidelines were followed throughout the systematic review, and the review was registered in PROSPERO (CRD42023424716). Studies published between 2010 and 2025 were accounted through 17 databases. The studies on medical device errors in adult, pediatric, and neonatal ICUs were encompassed, and the outcomes were synthesized qualitatively.
Results:
Seventy-two studies were covered and infusion pumps, syringe pumps, ventilators, and monitoring equipments were majorly associated with medical device errors. Errors were primarily related with human factors, device design flaws, and system failures. Infusion pump errors occurred in 60% of infusion initiations (80,209/133,601), while 89% of arrhythmia alarms were false positive among 2.5 million monitor alerts recorded in a cohort of 461 ICU patients.
Conclusion:
Medical device errors in ICUs are multifactorial. Effective prevention requires integrated approaches encompassing human factors engineering, focused training, improved device design, and a strong resilient patient safety culture.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
09:57A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Related Concept Videos
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies. Common...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Errors occurring during blood pressure monitoring
Several factors...
Cardiac Catheterization I: Pre-Procedure Overview
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications