Related Experiment Video
Updated: Mar 27, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Preventing Inadvertent Cannulation Into the Vein of Marshall With a Useful Fluoroscopic Landmark
Tomonobu Yanase1, Nobuhiko Ueda1, Shumpei Mori2
1Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Osaka, Japan.
Background:
Coronary sinus (CS) injury is a potentially serious complication during left ventricular lead implantation. Its risk may be reduced by recognizing atypical guidewire trajectories.
Case Summary:
A 71-year-old man with wild-type transthyretin cardiac amyloidosis underwent implantation of a cardiac resynchronization therapy device. During left ventricular lead placement, CS dissection occurred owing to the cannulation of a guiding catheter into the vein of Marshall (VOM) via an inadvertent guidewire. The patient remained hemodynamically stable, the CS dissection resolved spontaneously, and the procedure was completed successfully.
Discussion:
The VOM courses between the left atrial appendage and the left pulmonary veins. The third mogul, which corresponds to the left atrial appendage, may serve as a useful anatomical landmark to indicate inadvertent guidewire entry into the VOM.
Take-Home Message:
Identifying the third mogul on anteroposterior fluoroscopic view could facilitate early detection of inadvertent guidewire entry into the VOM and help prevent coronary venous complications.