A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Bluetooth low energy thermohygrometric sensor for continuous respiratory rate monitoring: 48 h breathing simulator
Dylan Rowe1, Mariam Rowe2, Phillip Melksham3
1School of Medicine, Griffith University, Brisbane, (QLD), Australia.
Abstract:
Continuous respiratory rate monitoring is essential for early detection of clinical deterioration, but conventional methods like capnography are often impractical outside high-acuity settings. We developed a low-cost, Bluetooth Low Energy (BLE) respiratory rate monitor incorporating a MEMS temperature-humidity sensor (AHT21) and Nordic nRF52840 microcontroller, designed to attach externally to a standard oxygen mask. The device detects breaths using rapid, cyclic changes in exhaled temperature and humidity via a slope-based time-domain algorithm. Bench validation over 48 h using a breathing simulator (5-60 breaths min-1, tidal volume 300 ml, 34 °C, 95%-100% RH) demonstrated 96.4% overall breath detection accuracy and strong correlation with programmed rates (r = 0.996, P < 0.0001). Sensor saturation occurred at high respiratory rates (60 breaths min-1), and high ambient humidity levels (90% RH) both of which reduced measurement accuracy. Human testing in three healthy adults showed strong agreement with capnography (mean bias 0.44 breaths min-1; 95% limits of agreement -1.86 to 2.75), with minor under-detection at the highest rate (50 breaths min-1). The device operated reliably across oxygen flow rates of 4-15 l min-1, with reduced performance at 0-2 l min-1due to saturation of the sensor. These results demonstrate that BLE-enabled MEMS thermohygrometric sensors can accurately monitor respiratory rate under controlled conditions while highlighting operational limits due to sensor saturation. This study extends prior work on humidity-based respiratory monitoring and illustrates the potential for low-cost, portable respiratory rate devices suitable for low-acuity or resource-limited clinical settings.
More Related Videos
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
06:26Author Spotlight: Exploring Breathing Techniques and Digital Solutions for Enhancing Running Performance
Published on: September 27, 2024
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...