Continuous blood pressure monitoring via hemodynamic parameter and pulse transit time derived from capacitive sensing
Yu-Jen Cheng1, Edward Kim2, Jin-Oh Hahn3
1Mechanical Engineering Department, University of Washington, Seattle, WA 98195, United States of America.
Abstract:
Objective.Continuous blood pressure (BP) monitoring is crucial for detecting nocturnal hypertension and acute hemodynamic changes. Conventional cuff-based methods disrupt sleep and miss transient BP fluctuations from sleep-related events or instability. Cuffless methods, such as pulse transit time (PTT), offer potential but often struggle to reliably track acute BP fluctuations due to complex and nonlinear hemodynamics.Approach.We developed a capacitive sensing pad system incorporating PTT with additional hemodynamic features for unobtrusive, continuous BP monitoring in supine subjects. The pad contains ultra-sensitive single-electrode capacitive (SEC) sensors made from carbon nanotube composites. In passive contact, SEC sensor on the back of the chest captures intrathoracic blood volume changes through deep tissue permittivity and ballistocardiography, while another under the leg detects arterial pulse-induced tissue vibrations. PTT is derived from the temporal delay between chest and leg signals. A neural network model incorporates PTT and intrathoracic blood volume features to improve BP estimation.Main results.In human trials (N= 30) with arm-cuff reference, the system showed strong correlation (r⩾ 0.94), with a mean error (ME) ⩽ 0.1 mmHg and standard deviation (SD) ⩽ 5.6 mmHg. In a subset (N= 8) with continuous finger-cuff reference, it maintained strong correlation (r⩾ 0.89), with a ME ⩽ 0.2 mmHg and SD ⩽ 7.8 mmHg.Significance.These results suggest the possibility of bed-based unobtrusive and continuous BP monitoring in the supine position.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure