Multicenter analysis of nuclear cataract population parameters and their clinical correlations based on AS-OCT
Ziying Liu1, Lingxi Hu, Tianhang Liu
1From the School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China (Z. Liu, J. Liu); Research Institute of Trustworthy Autonomous Systems and Department of Computer Science and Engineering, Southern University of Science and Technology, Shenzhen, China (Z. Liu, Hu, T. Liu, Xiao, Zhang, Higashita, J. Liu); Department of Electronic and Information Engineering, Changchun University, Changchun, China (J. Liu); Department of Ophthalmology, Shenzhen People's Hospital (The First Affiliated Hospital, Southern University of Science and Technology; The Second Clinical Medical College, Jinan University), Shenzhen, Guangdong, China (Lin); Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand (Chansangpetch); Center of Excellence in Glaucoma, Chulalongkorn University, Bangkok, Thailand (Chansangpetch).
Purpose:
To investigate the extent of lens opacity image features measured by anterior segment optical coherence tomography (AS-OCT) and their association with disease severity based on Lens Opacities Classification System III (LOCS III) in eyes with nuclear cataract (NC) and to determine the diagnostic performance of relative features for grading of nuclear lens opacity.
Setting:
Multicenter study at 2 sites.
Design:
Clinical validation.
Methods:
A total of 127 individuals with different severity of NC were recruited from 2 different clinical centers: Thailand (Thai, n = 81) and Shenzhen, China (SZRM, n = 46). All patients underwent AS-OCT examination, images were graded under the LOCS III standard. Automated machine learning models were developed to extract the nuclear region annotation, and feature-based quantifiers were then analyzed and evaluated through classifying cataract severity based on disease severity according to LOCS III.
Results:
AS-OCT pixel-based features such as mean, variance, root mean square, interquartile range, and percentiles significantly correlate with NC grading ( P < .01). Features such as variance, standard deviation, and median showed high consistency, while kurtosis and skewness were negatively correlated. The prediction model achieved 0.81 accuracy on the SZRM center (F1 score 0.82) and 0.87 accuracy on the Thai center (F1 score 0.83).
Conclusions:
Automated AS-OCT image features have strong consistency in lens opacity grading. Potentials are also shown in supportive diagnosis and surgical planning in NC.
More Related Videos
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
06:15Author Spotlight: Anterior HR-OCT as a Non-Invasive Tool for Characterizing Ocular Surface Squamous Neoplasia
Published on: August 9, 2024
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview