Related Experiment Video
Updated: Mar 29, 2026

Size Exclusion Chromatography for Separating Extracellular Vesicles from Conditioned Cell Culture Media
Published on: May 13, 2022
Benchmarking size-exclusion chromatography columns for the analysis of therapeutic peptides and model
Mathias Buff1, Alexandre Goyon2, Kelly Zhang2
1School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland.
Abstract:
Eleven modern size-exclusion chromatography (SEC) columns, including prototype columns designed to minimize non-specific interactions, were systematically evaluated for the analysis of peptides and oligonucleotides. Column physical properties and chromatographic performance were assessed under various mobile phase conditions. Notably, a reduced plate height close to 1 was achieved for one prototype column, representing a marked improvement over typical SEC performance (2 < hmin < 3). Mobile phase composition was optimized to balance chromatographic efficiency and analyte denaturation. The most denaturing conditions (30 % acetonitrile, 0.1 % trifluoroacetic acid) provided the best performance for linear, macrocyclic, disulfide-constrained, and lipid-conjugated peptides by effectively suppressing hydrophobic and ionic interactions. Columns with pore sizes ≥ 100 Å showed optimal performance, with UP-SW2000, Biozen dSEC-1, and BioCore SEC-120 columns (100-125 Å) yielding the best results. Column and mobile phase selection were particularly critical for hydrophobic peptides such as liraglutide and semaglutide; for these analytes, a phosphate-based mobile phase containing 20 % isopropanol was proposed to limit denaturation and potentially enable the characterization of non-covalent aggregates. For oligonucleotides, mobile phase composition had a limited impact, whereas stationary phase chemistry was decisive. Only two columns (UP-SW2000 and ACQUITY Premier SEC 125 Å) provided acceptable separations, enabling resolution of n-2 and n-3 shortmer impurities of 20-mer linear and structured oligonucleotides with resolutions close to 1. Coupling two 150-mm SEC columns in series further enhanced shortmer separation within 30 min.
Related Concept Videos
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Ion-Exchange Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Affinity Chromatography
Principles Of Column Chromatography

